RADIATION EFFECTS ON COMMUNICATION PERFORMANCE OF RADIO FREQUENCY IDENTIFICATION TAGS
- Source :
- Health Physics. 99:680-687
- Publication Year :
- 2010
- Publisher :
- Ovid Technologies (Wolters Kluwer Health), 2010.
-
Abstract
- Radioactive materials (sources) are managed by bookkeeping and stocktaking. The radiation protection section staffs should check the sources manually. Annual effective dose concerning stocktaking of them are estimated at some mSv concerning fingers. A radio frequency identification (RFID) tag's absorbed dose is estimated at some dozen Gy. RFID for stocktaking automatically was devised. Radiation effects on the communication performance of RFID tags were investigated by using response times and read ranges as indices. The RFID system was composed of a computer, a detector, and transponders (tag) consisting of an integrated circuit chip and an antenna. The tag is joined to the source for identification. The tags were irradiated at doses between 5 and 5,000 Gy by an x-ray irradiator. The response times and the read ranges were tracked from 40 to 23,200 min after irradiation. Relative read ranges fluctuated between 0.9 and 1.1 in the dose region less than 2,000 Gy, but fluctuated greatly in the dose region beyond 2,000 Gy. Malfunctioning tags appeared from 3,000 Gy, and all tags malfunctioned in the dose region over 4,500 Gy. The threshold dose leading to malfunction was determined to be 2,100 Gy. Time variation of relative read ranges was classified into four patterns. The pattern shifted from pattern 1 to 4 when the dose was increased. The relative read ranges lengthened in pattern 1. The relative read rages were approximately 1.0 in pattern 2. The read ranges tentatively shortened, then recovered in pattern 3. The tags malfunctioned in pattern 4. Once the tags malfunctioned, they never recovered their performance. Radiation enhances or deteriorates communication performance depending on dosage. Tags can spontaneously recover from radiation deterioration. The time variation of the read ranges can be illustrated by enhancement, deterioration, and recovery. The mechanism of four patterns is explained based on the variation of the frequency harmonization strength and activation voltage by irradiation. The annual effective dose of radiation protection section staffs can be reduced considerably.
- Subjects :
- Time Factors
Epidemiology
business.industry
Health, Toxicology and Mutagenesis
Acoustics
Detector
Radiation
Radiation Dosage
Effective dose (radiation)
Radio Frequency Identification Device
Threshold dose
Absorbed dose
Telecommunications
Radio-frequency identification
Equipment Failure
Radiology, Nuclear Medicine and imaging
Irradiation
Radiation protection
business
Mathematics
Subjects
Details
- ISSN :
- 00179078
- Volume :
- 99
- Database :
- OpenAIRE
- Journal :
- Health Physics
- Accession number :
- edsair.doi.dedup.....1e31b62b6638e279ceaf7bc96a75af6c
- Full Text :
- https://doi.org/10.1097/hp.0b013e3181e28be4