Back to Search
Start Over
IMAGE QUALITY STUDY OF RADIATION-REDUCED COMBINED CHEST AND ABDOMEN/PELVIS CT COMPARED WITH A STANDARD PROTOCOL
- Source :
- Radiation protection dosimetry. 196(3-4)
- Publication Year :
- 2021
-
Abstract
- The purpose of this study is to examine radiation doses and image quality of a low-dose (LD) protocol for chest and abdomen/pelvis (CAP) CT compared with a standard (STD) protocol. A total of 361 patients were included between October 2019 and April 2020; 104 patients with LD-protocol (100 kV, ref mAs 80 (chest)/145 (abdomen/pelvis)) and 257 patients with STD-protocol (100 kV, ref mAs 100 (chest)/180 (abdomen/pelvis)) at second-generation dual-source CT. Radiation doses for CTDIvol and DLP, and objective and subjective image qualities of 50 examinations from each group were evaluated. The LD-protocol applied significantly lower radiation doses compared with the STD-protocol (p
- Subjects :
- Radiation
Radiological and Ultrasound Technology
Image quality
business.industry
Medizin
Public Health, Environmental and Occupational Health
Abdomen+Pelvis
Good image
General Medicine
Thorax
Radiation Dosage
Pelvis
medicine.anatomical_structure
Abdomen
Standard protocol
Medicine
Humans
Radiology, Nuclear Medicine and imaging
Dose reduction
business
Nuclear medicine
Tomography, X-Ray Computed
CT protocol
Subjects
Details
- ISSN :
- 17423406
- Volume :
- 196
- Issue :
- 3-4
- Database :
- OpenAIRE
- Journal :
- Radiation protection dosimetry
- Accession number :
- edsair.doi.dedup.....1de1c495cae4c257697a39d5b2af65da