Back to Search Start Over

Magnetic diagnostics for the lithium tokamak experiment

Authors :
R. Kaita
Richard Majeski
T. A. Kozub
L. Berzak
Leonid E. Zakharov
Source :
The Review of scientific instruments. 79(10)
Publication Year :
2008

Abstract

The lithium tokamak experiment (LTX) is a spherical tokamak with R(0)=0.4 m, a=0.26 m, B(TF) approximately 3.4 kG, I(P) approximately 400 kA, and pulse length approximately 0.25 s. The focus of LTX is to investigate the novel low-recycling lithium wall operating regime for magnetically confined plasmas. This regime is reached by placing an in-vessel shell conformal to the plasma last closed flux surface. The shell is heated and then coated with liquid lithium. An extensive array of magnetic diagnostics is available to characterize the experiment, including 80 Mirnov coils (single and double axis, internal and external to the shell), 34 flux loops, 3 Rogowskii coils, and a diamagnetic loop. Diagnostics are specifically located to account for the presence of a secondary conducting surface and engineered to withstand both high temperatures and incidental contact with liquid lithium. The diagnostic set is therefore fabricated from robust materials with heat and lithium resistance and is designed for electrical isolation from the shell and to provide the data required for highly constrained equilibrium reconstructions.

Details

ISSN :
10897623
Volume :
79
Issue :
10
Database :
OpenAIRE
Journal :
The Review of scientific instruments
Accession number :
edsair.doi.dedup.....1cd2c33dc1603f3dda0158b428c1b222