Back to Search Start Over

Determination of REEs in seawater by ICP-MS after on-line preconcentration using a syringe-driven chelating column

Authors :
Kazumi Inagaki
Tomonari Umemura
Koichi Chiba
Yanbei Zhu
Hiroki Haraguchi
Source :
Talanta. 78:891-895
Publication Year :
2009
Publisher :
Elsevier BV, 2009.

Abstract

A syringe-driven chelating column (SDCC) was applied to develop an on-line preconcentration/inductively coupled plasma mass spectrometry (ICP-MS) method for preconcentration and determination of rare earth elements (REEs) in seawater samples. The present on-line preconcentration system consists of only one pump, two valves, an SDCC, an ICP-MS, several connectors, and Teflon tubes. Optimizations of adsorption pH condition, sample loading flow rate, and integration range were carried out to achieve optimum measurement conditions for REEs in seawater sample. Six minutes was enough for a preconcentration and measurement cycle using 10 mL of seawater sample, where the detection limits for different REEs were in the range of 0.005 pg mL−1 to 0.09 pg mL−1. Analytical results of REEs in a seawater certified reference material (CRM), NASS-5, confirmed the usefulness of the present method. Furthermore, concentrations of REEs in Nikkawa Beach coastal seawater were determined and discussed with shale normalized REE distribution pattern.