Back to Search
Start Over
Deep Laser-Assisted Lamellar Anterior Keratoplasty With Microkeratome-Cut Grafts
- Source :
- Cornea. 35:706-712
- Publication Year :
- 2016
- Publisher :
- Ovid Technologies (Wolters Kluwer Health), 2016.
-
Abstract
- PURPOSE The goals of this laboratory study were to evaluate the interface quality in laser-assisted lamellar anterior keratoplasty (LALAK) with microkeratome-cut grafts and achieve good graft-host apposition. METHODS Simulated LALAK surgeries were performed on 6 pairs of eye-bank corneoscleral discs. Anterior lamellar grafts were precut with microkeratomes. Deep femtosecond (FS) laser cuts were performed on host corneas followed by excimer laser smoothing. Different parameters of FS laser cuts and excimer laser smoothing were tested. Optical coherence tomography was used to measure corneal pachymetry and evaluate graft-host apposition. The interface quality was quantified in a masked fashion using a 5-point scale based on scanning electron microscopy images. RESULTS Deep FS laser cuts at 226 to 380 μm resulted in visible ridges on the host bed. Excimer laser smoothing with a central ablation depth of 29 μm and saline as a smoothing agent did not adequately reduce ridges (score = 4.0). Deeper excimer laser ablation of 58 μm and Optisol-GS as a smoothing agent smoothed ridges to an acceptable level (score = 2.1). Same sizing of the graft and host cut diameters with an approximately 50-μm deeper host side cut relative to the central graft thickness provided the best graft-host fit. CONCLUSIONS Deep excimer laser ablation with a viscous smoothing agent was needed to remove ridges after deep FS lamellar cuts. The host side cut should be deep enough to accommodate thicker graft peripheral thickness compared with the center. This LALAK design provides smooth lamellar interfaces, moderately thick grafts, and good graft-host fits.
- Subjects :
- Materials science
Corneal Pachymetry
Corneal Stroma
medicine.medical_treatment
Eye Banks
Article
law.invention
Cornea
Corneal Transplantation
03 medical and health sciences
0302 clinical medicine
Optics
Optical coherence tomography
law
Microkeratome
medicine
Humans
Lamellar structure
Corneal pachymetry
Fourier Analysis
medicine.diagnostic_test
Excimer laser
business.industry
Ablation
Laser
Tissue Donors
Ophthalmology
Microscopy, Electron, Scanning
030221 ophthalmology & optometry
Lasers, Excimer
business
Sclera
Tomography, Optical Coherence
030217 neurology & neurosurgery
Smoothing
Subjects
Details
- ISSN :
- 02773740
- Volume :
- 35
- Database :
- OpenAIRE
- Journal :
- Cornea
- Accession number :
- edsair.doi.dedup.....1c4e71f95bbe994477d84a97529c6dd6
- Full Text :
- https://doi.org/10.1097/ico.0000000000000783