Back to Search
Start Over
Comparison of image quality and radiation dose between split-filter dual-energy images and single-energy images in single-source abdominal CT
- Source :
- European radiology. 28(8)
- Publication Year :
- 2017
-
Abstract
- To compare image quality and radiation dose of abdominal split-filter dual-energy CT (SF-DECT) combined with monoenergetic imaging to single-energy CT (SECT) with automatic tube voltage selection (ATVS). Two-hundred single-source abdominal CT scans were performed as SECT with ATVS (n = 100) and SF-DECT (n = 100). SF-DECT scans were reconstructed and subdivided into composed images (SF-CI) and monoenergetic images at 55 keV (SF-MI). Objective and subjective image quality were compared among single-energy images (SEI), SF-CI and SF-MI. CNR and FOM were separately calculated for the liver (e.g. CNRliv) and the portal vein (CNRpv). Radiation dose was compared using size-specific dose estimate (SSDE). Results of the three groups were compared using non-parametric tests. Image noise of SF-CI was 18% lower compared to SEI and 48% lower compared to SF-MI (p 0.628). Subjective sharpness was equal between single-energy and monoenergetic images and diagnostic confidence was equal between single-energy and composed images. FOMliv was highest for SF-CI. FOMpv was equal for SEI and SF-MI (p = 0.78). SSDE was significant lower for SF-DECT compared to SECT (p < 0.022). The combined use of split-filter dual-energy CT images provides comparable objective and subjective image quality at lower radiation dose compared to single-energy CT with ATVS. • Split-filter dual-energy results in 18% lower noise compared to single-energy with ATVS. • Split-filter dual-energy results in 11% lower SSDE compared to single-energy with ATVS. • Spectral shaping of split-filter dual-energy leads to an increased dose-efficiency.
- Subjects :
- Adult
Male
Radiography, Abdominal
medicine.medical_specialty
Image quality
Abdominal ct
Signal-To-Noise Ratio
Radiation Dosage
030218 nuclear medicine & medical imaging
Spectral shaping
Radiography, Dual-Energy Scanned Projection
03 medical and health sciences
Young Adult
0302 clinical medicine
Image noise
Image Processing, Computer-Assisted
Medicine
Humans
Radiology, Nuclear Medicine and imaging
Aged
Retrospective Studies
Aged, 80 and over
business.industry
Ultrasound
Radiation dose
General Medicine
Filter (signal processing)
Middle Aged
030220 oncology & carcinogenesis
Female
Radiology
business
Nuclear medicine
Tomography, X-Ray Computed
Energy (signal processing)
Subjects
Details
- ISSN :
- 14321084
- Volume :
- 28
- Issue :
- 8
- Database :
- OpenAIRE
- Journal :
- European radiology
- Accession number :
- edsair.doi.dedup.....1bae5aea4fd44edba56b92c0d3cb6dbf