Back to Search
Start Over
CT of the normal temporal bone: comparison of multi- and single-detector row CT
- Source :
- Radiology. 235(1)
- Publication Year :
- 2005
-
Abstract
- To evaluate multi- and single-detector row computed tomographic (CT) depiction of anatomic landmarks of temporal bone.Institutional review board approval and written informed consent were obtained. In 50 temporal bones, transverse and coronal single-detector row CT images were compared with transverse and reformatted coronal multi-detector row CT images obtained of additional 50 temporal bones. Two radiologists evaluated images. Visibility of 50 landmarks was scored with a five-point quality rating scale. Fisher exact test, kappa statistics, and Mann-Whitney U test were used to evaluate imaging technique and landmark visibility.In delineating landmarks, total interobserver agreement was higher (P.001) for transverse multi- than for single-detector row CT images. In 60% of landmarks, interobserver agreement was higher (P.001) for transverse multi- than for single-detector row CT images. In 20% of landmarks, there was no difference, and in another 20% of landmarks, interobserver agreement was higher (P.01) for single-detector row CT. Total interobserver agreement was higher (P.01) for coronal multi-detector row reformations than for coronal single-detector row images. In 58% of landmarks, interobserver agreement was higher (P.001) for coronal multi-detector row reformations than for coronal single-detector row images, while there was no difference in 8%. In 34% of landmarks, interobserver agreement was higher (P.001) for coronal single-detector row images. Frequency of detected landmarks was higher for transverse (82%) and coronal (88%) multi-detector row images than for corresponding single-detector row images. In 72% of landmarks, transverse multi-detector row images were (P.05) superior to corresponding transverse single-detector row images in landmark delineation. In 56% of landmarks, reformatted coronal multi-detector row images were (P.05) superior to coronal single-detector row images in landmark delineation.Multi-detector row CT images, including reformations, better delineate temporal bone anatomy than do single-detector row CT images.
- Subjects :
- Male
Observer Variation
business.industry
Detector
Temporal Bone
Middle Aged
Computed tomographic
Transverse plane
Quality Rating Scale
Reference Values
Coronal plane
Temporal bone
Medicine
Humans
Radiology, Nuclear Medicine and imaging
Female
Imaging technique
Prospective Studies
Nuclear medicine
business
Tomography, X-Ray Computed
Subjects
Details
- ISSN :
- 00338419
- Volume :
- 235
- Issue :
- 1
- Database :
- OpenAIRE
- Journal :
- Radiology
- Accession number :
- edsair.doi.dedup.....1af2c9280495ff657d7a635ea8df8b24