Back to Search Start Over

Low-energy X-ray performance of SOI pixel sensors for astronomy, 'XRPIX'

Authors :
Shoji Kawahito
Yuki Amano
Ikuo Kurachi
Takahiro Hida
Masataka Yukumoto
Koji Mori
Takeshi Go Tsuru
Mitsuki Hayashida
Ayaki Takeda
Kazuho Kayama
Keita Yasutomi
Takaaki Tanaka
Ryota Kodama
Hiroki Kamehama
Yoshio Arai
Kouichi Hagino
Masatoshi Kitajima
Yusuke Nishioka
Hiroyuki Uchida
Takayoshi Kohmura
Source :
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 986:164745
Publication Year :
2021
Publisher :
Elsevier BV, 2021.

Abstract

We have been developing a new type of X-ray pixel sensors, "XRPIX", allowing us to perform imaging spectroscopy in the wide energy band of 1-20 keV for the future Japanese X-ray satellite "FORCE". The XRPIX devices are fabricated with complementary metal-oxide-semiconductor silicon-on-insulator technology, and have the "Event-Driven readout mode", in which only a hit event is read out by using hit information from a trigger output function equipped with each pixel. This paper reports on the low-energy X-ray performance of the "XRPIX6E" device with a Pinned Depleted Diode (PDD) structure. The PDD structure especially reduces the readout noise, and hence is expected to largely improve the quantum efficiencies for low-energy X-rays. While F-K X-rays at 0.68 keV and Al-K X-rays at 1.5 keV are successfully detected in the "Frame readout mode", in which all pixels are read out serially without using the trigger output function, the device is able to detect Al-K X-rays, but not F-K X-rays in the Event-Driven readout mode. Non-uniformity is observed in the counts maps of Al-K X-rays in the Event-Driven readout mode, which is due to region-to-region variation of the pedestal voltages at the input to the comparator circuit. The lowest available threshold energy is 1.1 keV for a small region in the device where the non-uniformity is minimized. The noise of the charge sensitive amplifier at the sense node and the noise related to the trigger output function are ~$18~e^-$ (rms) and ~$13~e^-$ (rms), respectively.<br />Comment: 8 pages, 10 figures, accepted for publication in NIMA, proceedings of the 12th International "Hiroshima" Symposium on the Development and Application of Semiconductor Tracking Detector (HSTD12)

Details

ISSN :
01689002
Volume :
986
Database :
OpenAIRE
Journal :
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Accession number :
edsair.doi.dedup.....1aad1fb61fdf7827d6fbd47dbee288d0