Back to Search Start Over

Anisotropic cellular forces support mechanical integrity of the Stratum Corneum barrier

Authors :
Mark Donovan
Yves Pomeau
Shuo Guo
Gustavo S. Luengo
Yegor A. Domanov
Eric Perez
Bertrand Ducos
Christine Gourier
Laboratoire de Physique Statistique de l'ENS (LPS)
Fédération de recherche du Département de physique de l'Ecole Normale Supérieure - ENS Paris (FRDPENS)
École normale supérieure - Paris (ENS Paris)
Université Paris sciences et lettres (PSL)-Université Paris sciences et lettres (PSL)-Centre National de la Recherche Scientifique (CNRS)-École normale supérieure - Paris (ENS Paris)
Université Paris sciences et lettres (PSL)-Université Paris sciences et lettres (PSL)-Centre National de la Recherche Scientifique (CNRS)-Université Paris Diderot - Paris 7 (UPD7)-Sorbonne Université (SU)-Centre National de la Recherche Scientifique (CNRS)
Mécanismes Moléculaires Membranaires
Laboratoire de physique de l'ENS - ENS Paris (LPENS (UMR_8023))
Université Paris sciences et lettres (PSL)-Université Paris sciences et lettres (PSL)-Centre National de la Recherche Scientifique (CNRS)-Sorbonne Université (SU)-Université Paris Diderot - Paris 7 (UPD7)-École normale supérieure - Paris (ENS Paris)
Université Paris sciences et lettres (PSL)-Université Paris sciences et lettres (PSL)-Centre National de la Recherche Scientifique (CNRS)-Sorbonne Université (SU)-Université Paris Diderot - Paris 7 (UPD7)
L'Oréal Research
L'OREAL
L'Oréal Recherche France (L'Oréal Recherche)
Centre National de la Recherche Scientifique (CNRS)-École normale supérieure - Paris (ENS Paris)-Centre National de la Recherche Scientifique (CNRS)-École normale supérieure - Paris (ENS Paris)-Université Paris Diderot - Paris 7 (UPD7)-Sorbonne Université (SU)-Centre National de la Recherche Scientifique (CNRS)
Dept. of Mathematics, University of Arizona (Dept. of Mathematics, University of Arizona)
University of Arizona
Université Paris Diderot - Paris 7 (UPD7)-Université Pierre et Marie Curie - Paris 6 (UPMC)-Centre National de la Recherche Scientifique (CNRS)-Fédération de recherche du Département de physique de l'Ecole Normale Supérieure - ENS Paris (FRDPENS)
Centre National de la Recherche Scientifique (CNRS)-École normale supérieure - Paris (ENS Paris)-Centre National de la Recherche Scientifique (CNRS)-École normale supérieure - Paris (ENS Paris)
Source :
Journal of the mechanical behavior of biomedical materials, Journal of the mechanical behavior of biomedical materials, Elsevier, 2019, 92, pp.11-23. ⟨10.1016/j.jmbbm.2018.12.027⟩
Publication Year :
2019
Publisher :
HAL CCSD, 2019.

Abstract

International audience; The protective function of biological surfaces that are exposed to the exterior of living organisms is the result of a complex arrangement and interaction of cellular components. This is the case for the most external cornified layer of skin, the stratum corneum (SC). This layer is made of corneocytes, the elementary ‘flat bricks’ that are held together through adhesive junctions. Despite the well-known protective role of the SC under high mechanical stresses and rapid cell turnover, the subtleties regarding the adhesion and mechanical interaction among the individual corneocytes are still poorly known. Here, we explore the adhesion of single corneocytes at different depths of the SC, by pulling them using glass microcantilevers, and measuring their detachment forces. We measured their interplanar adhesion between SC layers, and their peripheral adhesion among cells within a SC layer. Both adhesions increased considerably with depth. At the SC surface, with respect to adhesion, the corneocyte population exhibited a strong heterogeneity, where detachment forces differed by more than one order of magnitude for corneocytes located side by side. The measured detachment forces indicated that in the upper-middle layers of SC, the peripheral adhesion was stronger than the interplanar one. We conclude that the stronger peripheral adhesion of corneocytes in the SC favors an efficient barrier which would be able to resist strong stresses.

Details

Language :
English
ISSN :
17516161 and 18780180
Database :
OpenAIRE
Journal :
Journal of the mechanical behavior of biomedical materials, Journal of the mechanical behavior of biomedical materials, Elsevier, 2019, 92, pp.11-23. ⟨10.1016/j.jmbbm.2018.12.027⟩
Accession number :
edsair.doi.dedup.....1a80c4346bb1ed5aeb6d565e96ee12eb