Back to Search Start Over

Comparative study of cell saver and ultrafiltration nontransfusion in cardiac surgery

Authors :
M. Oe
Nakamura Y
Munetaka Masuda
Jirou Tanaka
Yoshihiro Toshima
Kouichi Tokunaga
T. Asou
Kazuhiko Kinoshita
Yoshito Kawachi
Source :
The Annals of Thoracic Surgery. 49:973-978
Publication Year :
1990
Publisher :
Elsevier BV, 1990.

Abstract

Hemoconcentration for the establishment of no-donor blood transfusion in open heart surgery was assessed in regard to both the saving of protein and platelets and the exclusion of free hemoglobin. Two different types of hemoconcentrator were compared: the ultrafilter (group I, 6 patients) and the Cell Saver (group II, 6 patients). The total serum protein level, expressed as the percent recovery of the preoperative value, after hemoconcentration was significantly higher in group I (group I versus group II: total serum protein, 118% versus 87% [p less than 0.05]; fibrinogen, 77% versus 50% [p less than 0.01]; immunoglobulin, 83% versus 60% [p less than 0.01]). The platelets also seemed to be well preserved after hemoconcentration in group I. Although the exclusion of free hemoglobin from plasma was inferior in group I compared with group II, the postoperative plasma free hemoglobin level did not increase in group I. We conclude that use of the Cell Saver in nontransfusion cardiopulmonary bypass might cause a severe depletion of various proteins and that the ultrafilter is both safer and more useful if employed routinely.

Details

ISSN :
00034975
Volume :
49
Database :
OpenAIRE
Journal :
The Annals of Thoracic Surgery
Accession number :
edsair.doi.dedup.....1a7232eaa2a62195abac765e9dc4b20d
Full Text :
https://doi.org/10.1016/0003-4975(90)90879-b