Modern principles of cardiotocography in childbirth
- Source :
- Медицинский совет, Vol 0, Iss 3, Pp 90-97 (2020)
- Publication Year :
- 2020
- Publisher :
- Remedium, Ltd., 2020.
-
Abstract
- Cardiotocography (CTG) is the main method of assessment of the fetus, which due to its informativeness and stability of the information obtained has almost completely replaced the phonoand electrocardiography of the fetus from the clinical practice. A CTG can be used to monitor the fetus during both pregnancy and delivery. Depending on the presence or absence of risk factors, internal or external CTGs are now used. Knowledge of the basic principles, definitions and concepts of CTG, its classification, as well as accumulated clinical experience, helps to interpret the results obtained and improve the outcomes of childbirth. CTG data should be considered in combination with the clinical situation in order to select the correct management of birth tactics and decide on the method of delivery. A recording made during delivery is a medical document that can be used for a comprehensive assessment of the course of delivery, as well as for legal protection of the clinician in complex situations. However, the method has insufficient specificity regarding the diagnosis of acute hypoxia. At present, there are no methods to accurately predict fetal hypoxia, and therefore, to solve this problem, CTG should be routinely performed on all new mothers. Increased experience with CTG helps to interpret the results and improves the outcome of childbirth. However, the method of delivery is always determined by the clinical situation. Despite the wide practical application of CTG, a number of unresolved issues remain, which requires further development of fetal monitoring methods.
- Subjects :
- congenital, hereditary, and neonatal diseases and abnormalities
medicine.medical_specialty
bradycardia
Fetal monitoring
03 medical and health sciences
0302 clinical medicine
Acute hypoxia
medicine
Childbirth
Cardiotocography
030212 general & internal medicine
Intensive care medicine
accelerations
Pregnancy
030219 obstetrics & reproductive medicine
medicine.diagnostic_test
hypoxia
business.industry
deceleration
General Medicine
medicine.disease
Clinical Practice
Fetal hypoxia
Legal protection
Medicine
cardiotocography
business
Subjects
Details
- ISSN :
- 26585790 and 2079701X
- Database :
- OpenAIRE
- Journal :
- Meditsinskiy sovet = Medical Council
- Accession number :
- edsair.doi.dedup.....19e431ee4c38d2a3a2fa73f38c572240
- Full Text :
- https://doi.org/10.21518/2079-701x-2020-3-90-97