Back to Search
Start Over
Performance characteristics of digital vs film screen mammography in community practice
- Source :
- The Breast Journal. 24:369-372
- Publication Year :
- 2017
- Publisher :
- Hindawi Limited, 2017.
-
Abstract
- We compared the performance characteristics of 297,629 full field digital (FFDM) and 416,791 screen film mammograms (SFM). Sensitivity increased with age, decreased with breast density, and was lower for more aggressive and lobular tumors. While sensitivity did not differ significantly by modality, specificity was generally 1–2 percentage points higher for FFDM than for SFM across age and breast density categories. The lower recall rate for FFDM vs. SFM in our study may partially explain performance differences by modality. In this large healthcare organization, modest gains in performance were achieved with the introduction of FFDM as a replacement for SFM.
- Subjects :
- Adult
medicine.medical_specialty
Breast Neoplasms
Sensitivity and Specificity
Article
Digital versus film photography
03 medical and health sciences
0302 clinical medicine
Breast cancer
Internal Medicine
Humans
Medicine
Mammography
Community Health Services
030212 general & internal medicine
Breast density
skin and connective tissue diseases
Aged
Breast Density
Gynecology
medicine.diagnostic_test
business.industry
Full field
Middle Aged
medicine.disease
Oncology
030220 oncology & carcinogenesis
Female
Surgery
Illinois
Radiology
Mammography screening
Recall rate
business
Subjects
Details
- ISSN :
- 1075122X
- Volume :
- 24
- Database :
- OpenAIRE
- Journal :
- The Breast Journal
- Accession number :