Back to Search Start Over

Are self-reported telemonitored blood pressure readings affected by end digit preference: a prospective cohort study in Scotland

Authors :
Paul L. Padfield
Vicky Hammersley
Adam Steventon
Janet Hanley
Hilary Pinnock
Richard A Parker
Brian McKinstry
Mary Paterson
Source :
Parker, R, Paterson, M, Padfield, P, Pinnock, H, Hanley, J, Hammersley, V, Steventon, A & McKinstry, B 2018, ' Are self-reported telemonitored blood pressure readings affected by end digit preference: a prospective cohort study in Scotland ', BMJ Open . https://doi.org/10.1136/bmjopen-2017-019431, BMJ Open
Publication Year :
2018

Abstract

ObjectiveSimple forms of blood pressure (BP) telemonitoring require patients to text readings to central servers creating an opportunity for both entry error and manipulation. We wished to determine if there was an apparent preference for particular end digits and entries which were just below target BPs which might suggest evidence of data manipulation.DesignProspective cohort studySetting37 socioeconomically diverse primary care practices from South East Scotland.ParticipantsPatients were recruited with hypertension to a telemonitoring service in which patients submitted home BP readings by manually transcribing the measurements into text messages for transmission (‘patient-texted system’). These readings were compared with those from primary care patients with uncontrolled hypertension using a system in which readings were automatically transmitted, eliminating the possibility of manipulation of values (‘automatic-transmission system’).MethodsA generalised estimating equations method was used to compare BP readings between the patient-texted and automatic-transmission systems, while taking into account clustering of readings within patients.ResultsA total of 44 150 BP readings were analysed on 1068 patients using the patient-texted system compared with 20 705 readings on 199 patients using the automatic-transmission system. Compared with the automatic-transmission data, the patient-texted data showed a significantly higher proportion of occurrences of both systolic and diastolic BP having a zero end digit (OR 2.1, 95% CI 1.7 to 2.6) although incidence was ConclusionEnd-digit preference for zero numbers and specific-value preference for readings just below the alert threshold exist among patients in self-reporting their BP using telemonitoring. However, the proportion of readings affected is small and unlikely to be clinically important.Trial registration numberISRCTN72614272; Post-results.

Details

Language :
English
Database :
OpenAIRE
Journal :
Parker, R, Paterson, M, Padfield, P, Pinnock, H, Hanley, J, Hammersley, V, Steventon, A & McKinstry, B 2018, ' Are self-reported telemonitored blood pressure readings affected by end digit preference: a prospective cohort study in Scotland ', BMJ Open . https://doi.org/10.1136/bmjopen-2017-019431, BMJ Open
Accession number :
edsair.doi.dedup.....184c914b2b34dd2aca341fb8f6a24831