Back to Search
Start Over
Accommodation and age-dependent eye model based on in vivo measurements
- Source :
- Journal of Optometry, Zapata-Díaz, J F, Radhakrishnan, H, Charman, W N & López-Gil, N 2018, ' Accommodation and age-dependent eye model based on in vivo measurements ', Journal of Optometry . https://doi.org/10.1016/j.optom.2018.01.003
- Publication Year :
- 2018
- Publisher :
- Elsevier, 2018.
-
Abstract
- Purpose To develop a flexible model of the average eye that incorporates changes with age and accommodation in all optical parameters, including entrance pupil diameter, under photopic, natural, environmental conditions. Methods We collated retrospective in vivo measurements of all optical parameters, including entrance pupil diameter. Ray-tracing was used to calculate the wavefront aberrations of the eye model as a function of age, stimulus vergence and pupil diameter. These aberrations were used to calculate objective refraction using paraxial curvature matching. This was also done for several stimulus positions to calculate the accommodation response/stimulus curve. Results The model predicts a hyperopic change in distance refraction as the eye ages (+0.22 D every 10 years) between 20 and 65 years. The slope of the accommodation response/stimulus curve was 0.72 for a 25 years-old subject, with little change between 20 and 45 years. A trend to a more negative value of primary spherical aberration as the eye accommodates is predicted for all ages (20–50 years). When accommodation is relaxed, a slight increase in primary spherical aberration (0.008 μm every 10 years) between 20 and 65 years is predicted, for an age-dependent entrance pupil diameter ranging between 3.58 mm (20 years) and 3.05 mm (65 years). Results match reasonably well with studies performed in real eyes, except that spherical aberration is systematically slightly negative as compared with the practical data. Conclusions The proposed eye model is able to predict changes in objective refraction and accommodation response. It has the potential to be a useful design and testing tool for devices (e.g. intraocular lenses or contact lenses) designed to correct the eye's optical errors.
- Subjects :
- Adult
Original article
Accommodation
Aging
genetic structures
Aberraciones
Eye model
Curvature
Modelo de ojo
Refraction, Ocular
Models, Biological
Pupil
Entrance pupil
03 medical and health sciences
Young Adult
0302 clinical medicine
Optics
Age
Humans
Edad
Acomodación
Pupila
Mathematics
Aged
Retrospective Studies
Wavefront
business.industry
Paraxial approximation
Accommodation, Ocular
Middle Aged
eye diseases
Spherical aberration
Aberrations
030221 ophthalmology & optometry
Female
sense organs
business
030217 neurology & neurosurgery
Photopic vision
Optometry
Subjects
Details
- Language :
- English
- ISSN :
- 19891342 and 18884296
- Volume :
- 12
- Issue :
- 1
- Database :
- OpenAIRE
- Journal :
- Journal of Optometry
- Accession number :
- edsair.doi.dedup.....18106c19f1fc5e9e0dd275a89bc98927
- Full Text :
- https://doi.org/10.1016/j.optom.2018.01.003