Back to Search Start Over

Integrity of the hip capsule measured with magnetic resonance imaging after capsular repair or unrepaired capsulotomy in hip arthroscopy

Authors :
Bech, Niels H.
van Dijk, Lode A.
de Waard, Sheryl
Vuurberg, Gwendolyn
Sierevelt, Inger N.
Kerkhoffs, Gino M. M. J.
Haverkamp, Daniēl
Graduate School
Amsterdam Movement Sciences
Orthopedic Surgery and Sports Medicine
AMS - Ageing & Vitality
AMS - Sports
VU University medical center
Surgery
Source :
Bech, N H, van Dijk, L A, de Waard, S, Vuurberg, G, Sierevelt, I N, Kerkhoffs, G M M J & Haverkamp, D 2022, ' Integrity of the hip capsule measured with magnetic resonance imaging after capsular repair or unrepaired capsulotomy in hip arthroscopy ', World Journal of Orthopaedics, vol. 13, no. 4, pp. 400-407 . https://doi.org/10.5312/wjo.v13.i4.400, World journal of orthopedics, 13(4), 400-407. di xue qian yuan bian ji bu, World Journal of Orthopaedics, 13(4), 400-407. di xue qian yuan bian ji bu
Publication Year :
2022

Abstract

BACKGROUND Current literature shows no clear answer on the question how to manage the capsule after hip arthroscopy. Regarding patient reported outcome measures there seems to be no difference between capsular repair or unrepaired capsulotomy. AIM To evaluate and compare the integrity of the hip capsule measured on a magnetic resonance imaging (MRI) scan after capsular repair or unrepaired capsulotomy. METHODS A case series study was performed; a random sample of patients included in a trial comparing capsular repair vs unrepaired capsulotomy had a postoperative MRI scan. The presence of a capsular defect and gap size were independently evaluated on MRI. RESULTS A total of 28 patients (29 hips) were included. Patient demographics were comparable between treatment groups. There were 2 capsular defects in the capsular repair group and 7 capsular defects in the unrepaired capsulotomy group (P = 0.13). In the group of patients with a defect, median gap sizes at the acetabular side were 5.9 mm (range: 2.7-9.0) in the repaired and 8.0 mm (range: 4.5-18.0) in the unrepaired group (P = 0.462). At the muscular side gap sizes were 6.6 mm (range: 4.1-9.0) in the repaired group and 11.5 mm (range: 3.0-18.0) in the unrepaired group (P = 0.857). The calculated Odds ratio (OR) for having a capsular defect with an increasing lateral center-edge (CE) angle was 1.12 (P = 0.06). The OR for having a capsular defect is lower in the group of patients that underwent a labral repair with an OR of 0.1 (P = 0.05). CONCLUSION There is no significant difference in capsular defects between capsular repair or unrepaired capsulotomy. Regarding clinical characteristics our case series shows that a larger CE angle increases the likelihood of a capsular defect and the presence of a labral repair decreases the likelihood of a capsular defect.

Details

Language :
English
ISSN :
22185836
Volume :
13
Issue :
4
Database :
OpenAIRE
Journal :
World journal of orthopedics
Accession number :