Back to Search Start Over

Analysis of tissue microstructure with Mueller microscopy: logarithmic decomposition and Monte Carlo modeling

Authors :
Tatiana Novikova
Florian Groeber-Becker
Pengcheng Li
Hee Ryung Lee
Razvigor Ossikovski
Shubham Chandel
Hui Ma
Christian Lotz
Sofia Dembski
Fraunhofer Institute for Silicate Research (Fraunhofer ISC)
Fraunhofer (Fraunhofer-Gesellschaft)
Laboratoire de physique des interfaces et des couches minces [Palaiseau] (LPICM)
École polytechnique (X)-Centre National de la Recherche Scientifique (CNRS)
Publica
Source :
Journal of Biomedical Optics, Journal of Biomedical Optics, Society of Photo-optical Instrumentation Engineers, 2020, 25 (01), pp.1. ⟨10.1117/1.JBO.25.1.015002⟩
Publication Year :
2020
Publisher :
HAL CCSD, 2020.

Abstract

Significance : Definitive diagnostics of many diseases is based on the histological analysis of thin tissue cuts with optical white light microscopy. Extra information on tissue structural properties obtained with polarized light would help the pathologist to improve the accuracy of his diagnosis. Aim: We report on using Mueller matrix microscopy data, logarithmic decomposition, and polarized Monte Carlo (MC) modeling for qualitative and quantitative analysis of thin tissue cuts to extract the information on tissue microstructure that is not available with a conventional white light microscopy. Approach: Unstained cuts of human skin equivalents were measured with a custom-built liquid-crystal-based Mueller microscope in transmission configuration. To interpret experimental data, we performed the simulations with a polarized MC algorithm for scattering anisotropic media. Several optical models of tissue (spherical scatterers within birefringent host medium, and combination of spherical and cylindrical scatterers within either isotropic or birefringent host medium) were tested. Results: A set of rotation invariants for the logarithmic decomposition of a Mueller matrix was derived to rule out the impact of sample orientation. These invariants were calculated for both simulated and measured Mueller matrices of the dermal layer of skin equivalents. We demonstrated that only the simulations with a model combining both spherical and cylindrical scatterers within birefringent host medium reproduced the experimental trends in optical properties of the dermal layer (linear retardance, linear dichroism, and anisotropic linear depolarization) with layer thickness. Conclusions: Our studies prove that Mueller polarimetry provides relevant information not only on a size of dominant scatterers (e.g., cell nuclei versus subwavelength organelles) but also on its shape (e.g., cells versus collagen fibers). The latter is directly related to the state of extracellular collagen matrix, which is often affected by early pathology. Hence, using polarimetric data can help to increase the accuracy of diagnosis.

Details

Language :
English
ISSN :
10833668
Database :
OpenAIRE
Journal :
Journal of Biomedical Optics, Journal of Biomedical Optics, Society of Photo-optical Instrumentation Engineers, 2020, 25 (01), pp.1. ⟨10.1117/1.JBO.25.1.015002⟩
Accession number :
edsair.doi.dedup.....17d0b58a6d5bc502a316fcb6c5c75df4
Full Text :
https://doi.org/10.1117/1.JBO.25.1.015002⟩