Radiochromic film-based quality assurance for CT-based high-dose-rate brachytherapy
- Source :
- Brachytherapy. 14(4)
- Publication Year :
- 2014
-
Abstract
- Purpose In the past, film dosimetry was developed into a powerful tool for external beam radiotherapy treatment verification and quality assurance. The objective of this work was the development and clinical testing of the EBT3 model GafChromic film based brachytherapy quality assurance (QA) system. Methods and Materials Retrospective dosimetry study was performed to test a patient-specific QA system for preoperative endorectal brachytherapy that uses a radiochromic film dosimetry system. A dedicated phantom for brachytherapy applicator used for rectal cancer treatment was fabricated enabling us to compare calculated-to-measured dose distributions. Starting from the same criteria used for external beam intensity-modulated radiation therapy QA (3%, 3 mm), passing criteria for high- and low-dose gradient regions were subsequently determined. Finally, we investigated the QA system's sensitivity to controlled source positional errors on selected patient plans. Results In low-dose gradient regions, measured dose distributions with criteria of 3%, 3 mm barely passed the test, as they showed 95% passing pixels. However, in the high-dose gradient region, a more stringent condition could be established. Both criteria of 2%, 3 mm and 3%, 2 mm with gamma function calculated using normalization to the same absolute dose value in both measured and calculated dose distributions, and matrix sizes rescaled to match each other showed more than 95% of pixels passing, on average, for 15 patient plans analyzed. Conclusions Although the necessity of the patient-specific brachytherapy QA needs yet to be justified, we described a radiochromic film dosimetry–based QA system that can be a part of the brachytherapy commissioning process, as well as yearly QA program.
- Subjects :
- medicine.medical_specialty
Film Dosimetry
Quality Assurance, Health Care
medicine.medical_treatment
Brachytherapy
Imaging phantom
030218 nuclear medicine & medical imaging
03 medical and health sciences
0302 clinical medicine
Medicine
Dosimetry
Humans
Radiology, Nuclear Medicine and imaging
Radiochromic film
Medical physics
External beam radiotherapy
Radiometry
Retrospective Studies
business.industry
Phantoms, Imaging
Rectal Neoplasms
Radiotherapy Dosage
High-Dose Rate Brachytherapy
3. Good health
Radiation therapy
Oncology
030220 oncology & carcinogenesis
Radiotherapy, Intensity-Modulated
business
Nuclear medicine
Tomography, X-Ray Computed
Quality assurance
Subjects
Details
- ISSN :
- 18731449
- Volume :
- 14
- Issue :
- 4
- Database :
- OpenAIRE
- Journal :
- Brachytherapy
- Accession number :
- edsair.doi.dedup.....14c70cad86951a589181abe7a3ec9527