Back to Search
Start Over
Use of urine lead level as an exposure indicator and its relationship to blood lead
- Source :
- Cadernos de Saúde Pública, Volume: 24, Issue: 9, Pages: 2151-2159, Published: SEP 2008, Cadernos de Saúde Pública v.24 n.9 2008, Cadernos de Saúde Pública, Fundação Oswaldo Cruz (FIOCRUZ), instacron:FIOCRUZ
- Publication Year :
- 2008
- Publisher :
- FapUNIFESP (SciELO), 2008.
-
Abstract
- O objetivo deste trabalho foi verificar se há correlação estatisticamente significativa entre as concentrações de chumbo no sangue (Pb-S) e urina (Pb-U). A espectrometria de absorção atômica eletrotérmica foi utilizada na determinação da concentração de chumbo no material biológico. As amostras de sangue e de urina foram coletadas entre trabalhadores expostos ocupacionalmente (95) e entre adultos (130) e crianças até 15 anos (22) expostos ambientalmente. Após um teste que mostrou diferenças significativas entre Pb-U e as três categorias previamente determinadas, pontos de corte em Pb-U puderam ser fixados para a predição dos valores de Pb-S pela curva ROC. Assim, para Pb-U até 0,55 µg.dL-1, pode-se esperar que Pb-S seja menor do que 10 µg.dL-1, ao passo que níveis de chumbo no sangue até 27,6 µg.dL-1 são esperados quando o teor do metal na urina é menor do que 2,05 µg.dL-1. Logo, a urina pode ser utilizada em substituição ao sangue para avaliação da exposição ocupacional ao chumbo. Contudo, recomenda-se cautela no caso da exposição ambiental, devendo-se utilizar o chumbo urinário como uma estimativa do conteúdo do metal no sangue. The aim of this work was to verify whether there are statistically significant correlation between the concentrations of lead in blood (Pb-B) and urine (Pb-U). Electrothermal atomic absorption spectrometry was used in the determination of lead concentration in biological material. Venous blood and spot urine were collected from workers occupationally exposed (95), adults (130) and children up to 15 years old (22) environmentally exposed. After a test showing significant differences between Pb-U and the three categories previously determined, cutting points for Pb-U were established to predict Pb-B values by the ROC curve. Thus, it is expected that Pb-B is lower than 10 µg.dL-¹ with Pb-U up to 0.55 µg. dL-¹, whereas lead levels in blood below 27.6 µg. dL-¹ are expected when the amount of the metal in urine is lower than 2.05 µg.dL-¹. So, urine can be used to replace blood for the assessment of the occupational exposure to lead. However, caution is advised in the case of environmental exposure, since urinary lead should be used just as an estimation of the metal content in blood.
- Subjects :
- Sangue
business.industry
Urinary system
Exposição Ocupacional
Urina
Public Health, Environmental and Occupational Health
Physiology
Venous blood
Urine
Environmental exposure
Biological materials
Chumbo
Spot urine
Blood
Lead
Occupational Exposure
Medicine
Occupational exposure
Lead (electronics)
business
Subjects
Details
- ISSN :
- 0102311X
- Volume :
- 24
- Database :
- OpenAIRE
- Journal :
- Cadernos de Saúde Pública
- Accession number :
- edsair.doi.dedup.....148e90c1b77faef6407524c43f64b176
- Full Text :
- https://doi.org/10.1590/s0102-311x2008000900021