Impact of advanced detector technology and iterative reconstruction on low-dose quantitative assessment of lung computed tomography density in a biological lung model
- Source :
- Medical Physics. 45:3657-3670
- Publication Year :
- 2018
- Publisher :
- Wiley, 2018.
-
Abstract
- Purpose Quantitative computed tomography (QCT)-derived measures of lung density are valued methods for objectively characterizing lung parenchymal and peripheral airways disease and are being used in a growing number of lung disease focused trials. Detector and reconstruction improvements in CT technology have allowed for significant radiation dose reduction in image acquisition with comparable qualitative image quality. We report the impact of detector type and reconstruction type on QCT lung density measures in relation to decreasing dose indices. Methods Two sets of studies were completed in an in vivo pig model with a SOMATOM Definition Flash CT system: (a) prior to system upgrade with conventional detectors (UFC) and filtered back projection (FBP), and (b) post system upgrade with integrated electronic detectors (STELLAR) and iterative reconstruction (SAFIRE). CT data were acquired across estimated CT volume dose indices (CTDIvol ) ranging from 0.75 to 15 mGy at both inspiratory and expiratory breath holds. Semiautomated lung segmentations allowed calculation of histogram median, kurtosis, and 15th percentile. Percentage of voxels below -910 HU and -950 HU (inspiratory), and -856 HU (expiratory) were also examined. The changes in these QCT metrics from dose reduction (15 mGy down to 0.75 mGy) were calculated relative to paired reference values (15 mGy). Results were compared based on detector and reconstruction type. Results In this study, STELLAR detectors improved concordance with 15 mGy values down to 3 mGy for inspiratory scans and 6 mGy for expiratory scans. The addition of SAFIRE reconstruction in all acquired measurements resulted in minimal deviation from reference values at 0.75 mGy. Conclusion The use of STELLAR integrated electronic detectors and SAFIRE iterative reconstruction may allow for comparable lung density measures with CT dose indices down to 0.75 mGy.
- Subjects :
- Percentile
medicine.diagnostic_test
Radon transform
business.industry
Image quality
Detector
General Medicine
Iterative reconstruction
computer.software_genre
Air trapping
Article
030218 nuclear medicine & medical imaging
03 medical and health sciences
0302 clinical medicine
030228 respiratory system
Voxel
medicine
medicine.symptom
Quantitative computed tomography
Nuclear medicine
business
computer
Subjects
Details
- ISSN :
- 00942405
- Volume :
- 45
- Database :
- OpenAIRE
- Journal :
- Medical Physics
- Accession number :
- edsair.doi.dedup.....137576187e3a38f0553b1b2e23c27d8e