Back to Search Start Over

Narrowing the difference in dose delivery for IOERT and IOBT for locally advanced and locally recurrent rectal cancer

Authors :
Verrijssen, An-Sofie E
Dries, Wim J F
Cnossen, Jeltsje S
Theuws, Jacqueline
Peulen, Heike M U
van den Berg, Hetty A
Rijkaart, Dorien C
Voogt, Eva L K
Kolkman-Deurloo, Inger-Karine
Nuyttens, Joost
Rutten, Harm J T
Burger, Jacobus W A
Bimmel-Nagel, Cathryn Huibregtse
Radiation Oncology
Radiotherapie
RS: GROW - R3 - Innovative Cancer Diagnostics & Therapy
RS: GROW - R2 - Basic and Translational Cancer Biology
Surgery
Source :
Journal of Contemporary Brachytherapy, 14(4), 370-378. Termedia Publishing House Ltd.
Publication Year :
2022
Publisher :
Termedia Publishing House Ltd., 2022.

Abstract

Purpose: Intra-operative radiotherapy (IORT) has been used as a tool to provide a high-dose radiation boost to a limited volume of patients with fixed tumors with a likelihood of microscopically involved resection margins, in order to improve local control. Two main techniques to deliver IORT include high-dose-rate (HDR) brachytherapy, termed 'intra-operative brachytherapy' (IOBT), and electrons, termed 'intra-operative electron radiotherapy' (IOERT), both having very different dose distributions. A recent paper described an improved local recurrence-free survival favoring IOBT over IOERT for patients with locally advanced or recurrent rectal cancer and microscopically irradical resections. Although several factors may have contributed to this result, an important difference between the two techniques was the higher surface dose delivered by IOBT. This article described an adaptation of IOERT technique to achieve a comparable surface dose as dose delivered by IOBT.Material and methods: Two steps were taken to increase the surface dose for IOERT: 1. Introducing a bolus to achieve a maximum dose on the surface, and 2. Re-normalizing to allow for the same prescribed dose at reference depth.Conclusions: We describe and propose an adaptation of IOERT technique to increase surface dose, decreasing the differences between these two techniques, with the aim of further improving local control. In addition, an alternative method of dose prescription is suggested, to consider improved comparison with other techniques in the future.

Details

Language :
English
ISSN :
1689832X
Volume :
14
Issue :
4
Database :
OpenAIRE
Journal :
Journal of Contemporary Brachytherapy
Accession number :
edsair.doi.dedup.....1331f1b7e12ed1c6701ea7c8b78244e5