Back to Search Start Over

Pre- and post-irradiation performance of FBK 3D silicon pixel detectors for CMS

Authors :
John Perry Cumalat
Frank Jensen
A. Vilela Pereira
S. Terzo
Ada Solano
Maria Margherita Obertino
A. Krzywda
Ian Shipsey
Maurizio Boscardin
Roberto Mendicino
C. M. Lei
A. Kumar
Kirk Arndt
Luigi Moroni
Dario Menasce
S. Tentindo
Nhan Tran
M. Bubna
M. Povoli
Ilya Osipenkov
Lorenzo Uplegger
Suvadeep Bose
Daniela Bortoletto
Simon Kwan
Stephen Robert Wagner
G.-F. Dalla Betta
J. Ngadiuba
Ping Tan
Gino Bolla
L. Perera
J. Adreson
A. Prosser
R. Brosius
E. Alagoz
J. Chramowicz
Ryan Rivera
Source :
NUCLEAR INSTRUMENTS and METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT. 763
Publication Year :
2014

Abstract

In preparation for the tenfold luminosity upgrade of the Large Hadron Collider (the HL-LHC) around 2020, three-dimensional (3D) silicon pixel sensors are being developed as a radiation-hard candidate to replace the planar ones currently being used in the CMS pixel detector. This study examines an early batch of FBK sensors (named ATLAS08) of three 3D pixel geometries: 1E, 2E, and 4E, which respectively contain one, two, and four readout electrodes for each pixel, passing completely through the bulk. We present electrical characteristics and beam test performance results for each detector before and after irradiation. The maximum fluence applied is 3.5×1015 n eq /cm2.