Back to Search
Start Over
RODRIGO et al
- Source :
- RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia, instname, Pacing and Clinical Electrophysiology, Repositorio Institucional de la Consejería de Sanidad de la Comunidad de Madrid, Consejería de Sanidad de la Comunidad de Madrid
- Publication Year :
- 2017
- Publisher :
- Blackwell Publishing, 2017.
-
Abstract
- [EN] Background: Ablation of drivers maintaining atrial fibrillation (AF) has been demonstrated as an effective therapy. Drivers in the form of rapidly activated atrial regions can be noninvasively localized to either left or right atria (LA, RA) with body surface potential mapping (BSPM) systems. This study quantifies the accuracy of dominant frequency (DF) measurements from reduced-leads BSPM systems and assesses the minimal configuration required for ablation guidance. Methods: Nine uniformly distributed lead sets of eight to 66 electrodes were evaluated. BSPM signals were registered simultaneously with intracardiac electrocardiograms (EGMs) in 16 AF patients. DF activity was analyzed on the surface potentials for the nine leads configurations, and the noninvasive measures were compared with the EGM recordings. Results: Surface DF measurements presented similar values than panoramic invasive EGM recordings, showing the highest DF regions in corresponding locations. The noninvasive DFs measures had a high correlation with the invasive discrete recordings; they presented a deviation of 0.8 for leads configurations with 12 or more electrodes. Conclusions: Reduced-leads BSPM systems enable noninvasive discrimination between LA versus RA DFs with similar results as higher-resolution 66-leads system. Our findings demonstrate the possible incorporation of simplified BSPM systems into clinical planning procedures for AF ablation.<br />This work was supported in part by Generalitat-Valenciana Grants [ACIF/2013/021]; Instituto de SaludCarlos III, Ministerio de Ciencia e Innovacion [PI13/00903, PI13-01882, PI14/00857, PI16/01123, TEC2013-46067-R, DTS16/0160 and IJCI-2014-22178] cofound by FEDER.; Spanish Society of Cardiology [Clinical research Grants 2015]; Ministerio de Ciencia e Innovacion [Red RICRD12.0042.0001]; and the National Heart, Lung, and Blood Institute [P01-HL039707, P01-HL087226 and R01-HL118304].
- Subjects :
- medicine.medical_specialty
medicine.medical_treatment
Body surface potential mapping
030204 cardiovascular system & hematology
Article
Intracardiac injection
TECNOLOGIA ELECTRONICA
03 medical and health sciences
Electrocardiography
0302 clinical medicine
Internal medicine
Body surface
medicine
Humans
Lead (electronics)
medicine.diagnostic_test
Dominant frequency
business.industry
Lead distribution
Atrial fibrillation
General Medicine
medicine.disease
Ablation
3. Good health
Cardiology
Cardiology and Cardiovascular Medicine
business
RIGHT DOMINANT
030217 neurology & neurosurgery
Subjects
Details
- Language :
- English
- ISSN :
- 20134606
- Database :
- OpenAIRE
- Journal :
- RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia, instname, Pacing and Clinical Electrophysiology, Repositorio Institucional de la Consejería de Sanidad de la Comunidad de Madrid, Consejería de Sanidad de la Comunidad de Madrid
- Accession number :
- edsair.doi.dedup.....11a0f6e2e315cc8c02b0e8d04fd2217d
- Full Text :
- https://doi.org/10.1111/pace.13133