Back to Search Start Over

Stress thallium-201/rest technetium-99m sequential dual-isotope high-speed myocardial perfusion imaging validation versus invasive coronary angiography

Authors :
Estelle Vautrin
Jacques Machecourt
Catherine Ghezzi
Gilles Barone-Rochette
Daniel Fagret
Gérald Vanzetto
Mélanie Leclere
Jean Philippe Baguet
Alexis Broisat
Gallazzini-Crepin Céline
Alex Calizzano
Radiopharmaceutiques biocliniques (LRB)
Institut National de la Santé et de la Recherche Médicale (INSERM)-Université Grenoble Alpes [2016-2019] (UGA [2016-2019])
Université Grenoble Alpes - UFR Médecine (UGA UFRM)
Université Grenoble Alpes [2016-2019] (UGA [2016-2019])
Centre Hospitalier Universitaire [Grenoble] (CHU)
Radiopharmaceutiques biocliniques
Université Joseph Fourier - Grenoble 1 (UJF)-Institut National de la Santé et de la Recherche Médicale (INSERM)
Clinique Cardiologie et Hypertension Artérielle
Université Joseph Fourier - Grenoble 1 (UJF)-CHU Grenoble-Hôpital Michallon
Université Joseph Fourier - Grenoble 1 (UJF)
Perret, Pascale
Source :
Journal of Nuclear Cardiology, Journal of Nuclear Cardiology, Springer Verlag, 2015, 22 (3), pp.513-522. ⟨10.1007/s12350-014-0016-0⟩, Journal of Nuclear Cardiology, 2015, 22 (3), pp.513-522. ⟨10.1007/s12350-014-0016-0⟩
Publication Year :
2015
Publisher :
HAL CCSD, 2015.

Abstract

Recent advances in nuclear myocardial perfusion imaging (MPI) have made it possible to develop a dual-isotope protocol for high-speed acquisition with image quality and radiation delivery comparable to that obtained with conventional single isotope protocols. So far, no study has compared dual-isotope high-speed MPI to invasive coronary angiography (ICA) in a large cohort using a Cadmium-zinc-telluride SPECT system. Over a 1-year period (May 2011 to April 2012), 1366 patients underwent dual-isotope high-speed MPI. Patients with ICA within 3 months after dual-isotope high-speed MPI were included together with patients with a low likelihood of coronary artery disease (CAD) in order to assess normalcy rate. Global summed stress score (SSS) and summed rest score (SRS) were calculated, and ICA results were analyzed independently. The main end point was a patient-based assessment of the diagnostic performance of dual-isotope high-speed MPI in detecting or ruling out significant CAD (>70% reduction in lumen diameter). Inclusion criteria were fulfilled for 214 patients (143 men; age 60 ± 14 years; ICA, n = 104; low likelihood for CAD, n = 110). An exercise stress test was performed in 62% of patients and a pharmacological stress test was performed with either dipyridamole (32%) or dobutamine (6%). Average examination duration was 22.4 ± 4.5 minutes. Mean SSS, SRS, and SDS were 8.0 ± 4.9, 3.1 ± 4.3, and 5.0 ± 3.2, respectively. Prevalence of angiographic CAD was 75%. ICA detected stenosis in the left main trunk, left anterior descending artery, left circumflex artery, and right coronary artery in 4, 33, 31, and 42 patients, respectively. Sensitivity of dual-isotope high-speed MPI was 94%, normalcy rate was 92%, and accuracy was 83% for detecting CAD. Dual-isotope high-speed MPI is reliable at detecting or ruling out CAD. NCT01785589