A rapid, reproducible, on-the-fly orthogonal array optimization method for targeted protein quantification by LC/MS and its application for accurate and sensitive quantification of carbonyl reductases in human liver
- Source :
- Analytical chemistry. 82(7)
- Publication Year :
- 2010
-
Abstract
- Liquid chromatography (LC)/mass spectrometry (MS) in selected-reactions-monitoring (SRM) mode provides a powerful tool for targeted protein quantification. However, efficient, high-throughput strategies for proper selection of signature peptides (SP) for protein quantification and accurate optimization of their SRM conditions remain elusive. Here we describe an on-the-fly, orthogonal array optimization (OAO) approach that enables rapid, comprehensive, and reproducible SRM optimization of a large number of candidate peptides in a single nanoflow-LC/MS run. With the optimized conditions, many peptide candidates can be evaluated in biological matrices for selection of the final SP. The OAO strategy employs a systematic experimental design that strategically varies product ions, de-clustering energy and collision energy in a cycle of 25 consecutive SRM trials, which accurately reveals the effects of these factors on the single-to-noise ratio of a candidate peptide, and optimizes each. As proof of concept, we developed a highly sensitive, accurate, and reproducible method for the quantification of carbonyl reductases CBR1 and CBR3 in human liver. Candidate peptides were identified by nano-LC/LTQ/Orbitrap, filtered using a stringent set of criteria, and subjected to OAO. After evaluating both sensitivity and stability of the candidates, two SP were selected for quantification of each protein. As a result of the accurate OAO of assay conditions, sensitivities of 80 and 110 amol were achieved for CBR1 and CBR3, respectively. The method was validated and used to quantify the CBRs in 33 human liver samples. The mean level of CBR1 was 93.4±49.7 (range: 26.2–241) ppm of total protein, and for CBR3 was 7.69±4.38 (range: 1.26–17.9) ppm. Key observations of this study are that: i) evaluation of peptide stability in the target matrix is essential for final selection of the SP; ii) utilization of two unique SP contributes to high reliability of target protein quantification; and iii) it is beneficial to construct calibration curves using standard proteins of verified concentrations to avoid severe biases that may result if synthesized peptides alone are used. Overall, the OAO method is versatile and adaptable to high-throughput quantification of validated biomarkers identified by proteomic discovery experiments.
- Subjects :
- chemistry.chemical_classification
Chromatography
Human liver
On the fly
Quantitative proteomics
Reproducibility of Results
Peptide
Mass spectrometry
Mass Spectrometry
Article
Analytical Chemistry
Protein Structure, Tertiary
Alcohol Oxidoreductases
chemistry
Liver
Liquid chromatography–mass spectrometry
Proof of concept
Humans
Amino Acid Sequence
Orthogonal array
Chromatography, High Pressure Liquid
Subjects
Details
- ISSN :
- 15206882
- Volume :
- 82
- Issue :
- 7
- Database :
- OpenAIRE
- Journal :
- Analytical chemistry
- Accession number :
- edsair.doi.dedup.....10cd04be8c3d468e0ee062973034e950