Back to Search
Start Over
Accuracy Evaluation of 14 Maxillary Full Arch Implant Treatments Performed with Da Vinci Bridge: A Case Series
- Source :
- Materials, Volume 13, Issue 12, Materials, Vol 13, Iss 2806, p 2806 (2020)
- Publication Year :
- 2020
- Publisher :
- Multidisciplinary Digital Publishing Institute, 2020.
-
Abstract
- The use of pterygoid implants can be an attractive alternative to sinus bone grafting in the treatment of posterior atrophic maxilla. This technique has not been widely used because of the difficulty of the surgical access, the presence of vital structures, and the prosthetic challenges. The use of dynamic computer aided implantology (DCAI) allows the clinician to utilize navigation dental implant surgery, which allows the surgeon to follow the osteotomy site and implant positioning in real time. A total of 14 patients (28 pterygoid implants and 56 intersinusal implants) were enrolled in the study for a full arch implant prosthetic rehabilitation (4 frontal implants and 2 pterygoids implants), using a dynamic navigation system. The reported accuracy of pterygoid implants inserted using DCAI was 0.72 mm at coronal point, 1.25 mm at apical 3D, 0.66 mm at apical depth, and 2.86&deg<br />as angular deviation. The use of pterygoid implants in lieu of bone grafting represents a valid treatment opportunity to carry out a safe, accurate, and minimally invasive surgery, while reducing treatment time and avoiding cantilevers for a full implant prosthetic rehabilitation of the upper arch.
- Subjects :
- medicine.medical_treatment
Bone grafting
lcsh:Technology
Article
03 medical and health sciences
0302 clinical medicine
stomatognathic system
medicine
Atrophic maxilla
General Materials Science
Arch
lcsh:Microscopy
Bridge (dentistry)
Sinus (anatomy)
lcsh:QC120-168.85
Orthodontics
lcsh:QH201-278.5
lcsh:T
business.industry
dynamic navigation implantology
030206 dentistry
totally edentulous patients
pterygoid implants
Surgical access
computer aided implantology
medicine.anatomical_structure
lcsh:TA1-2040
030220 oncology & carcinogenesis
Coronal plane
atrophic maxilla
lcsh:Descriptive and experimental mechanics
lcsh:Electrical engineering. Electronics. Nuclear engineering
Implant
lcsh:Engineering (General). Civil engineering (General)
business
lcsh:TK1-9971
Subjects
Details
- Language :
- English
- ISSN :
- 19961944
- Database :
- OpenAIRE
- Journal :
- Materials
- Accession number :
- edsair.doi.dedup.....10b05398fa7492a42fa162a0eb7f21ee
- Full Text :
- https://doi.org/10.3390/ma13122806