Back to Search Start Over

Determination of Cardiac Glycosides in Digitoxin Tablets and Deslanoside Injections by Micro-HPLC

Authors :
Youichi Fujii
Mitsuru Yamazaki
Yukari Ikeda
Source :
Journal of Chromatographic Science. 28:288-291
Publication Year :
1990
Publisher :
Oxford University Press (OUP), 1990.

Abstract

A micro high-performance liquid chromatographic (micro-HPLC) procedure for the assay of digitoxin tablets and deslanoside injections has been developed. Micro-HPLC is performed on an ODS micro column, with acetonitrile-methanol-water (10:20:17) for digitoxin tablets and acetonitrile-water (21:70) for deslanoside injections. The effluent is monitored by UV absorption at 220 nm. Quantitation of cardiac glycosides in tablets and injections is carried out by the internal standard method. The composite assay results for digitoxin tablets and deslanoside injections provide average values of 101.2 and 99.9% with standard deviations of 1.2 and 0.93%, respectively. This micro-HPLC method is sensitive, quantitative, and reproducible. It is suitable for use in examining the content uniformity of pharmaceutical preparations.

Details

ISSN :
1945239X and 00219665
Volume :
28
Database :
OpenAIRE
Journal :
Journal of Chromatographic Science
Accession number :
edsair.doi.dedup.....0ee77e11672cb0d1df9822e2652503c7
Full Text :
https://doi.org/10.1093/chromsci/28.6.288