Back to Search Start Over

Analysis of the human chorionic gonadotropin protein at the intact level by HILIC-MS and comparison with RPLC-MS

Authors :
Nathalie Delaunay
Julien Camperi
Audrey Combès
Valérie Pichon
Thierry Fournier
Laboratoire Sciences Analytiques, Bioanalytiques, et Miniaturisation (LSABM)
Chimie-Biologie-Innovation (UMR 8231) (CBI)
Institut de Chimie du CNRS (INC)-Centre National de la Recherche Scientifique (CNRS)-Ecole Superieure de Physique et de Chimie Industrielles de la Ville de Paris (ESPCI Paris)
Université Paris sciences et lettres (PSL)-Université Paris sciences et lettres (PSL)-Institut de Chimie du CNRS (INC)-Centre National de la Recherche Scientifique (CNRS)-Ecole Superieure de Physique et de Chimie Industrielles de la Ville de Paris (ESPCI Paris)
Université Paris sciences et lettres (PSL)-Université Paris sciences et lettres (PSL)
Physiopathologie et pharmacotoxicologie placentaire humaine : Microbiote pré & post natal (3PHM - UMR-S 1139)
Institut National de la Santé et de la Recherche Médicale (INSERM)-Université Paris Descartes - Paris 5 (UPD5)
Sorbonne Université (SU)
Source :
Analytical and Bioanalytical Chemistry, Analytical and Bioanalytical Chemistry, Springer Verlag, 2020, ⟨10.1007/s00216-020-02684-8⟩
Publication Year :
2020

Abstract

In the present work, the human chorionic gonadotropin (hCG) hormone was characterized for the first time by hydrophilic interaction liquid chromatography (HILIC) coupled to high-resolution (HR) quadrupole/time-of-flight (qTOF) mass spectrometry (MS) at the intact level. This heterodimeric protein, consisting of two subunits (hCGα and hCGβ), possesses 8 potential glycosylation sites leading to a high number of glycoforms and has a molecular weight of about 35 kDa. The HILIC conditions optimized in a first paper but using UV detection were applied here with MS for the analysis of two hCG-based drugs, a recombinant hCG and a hCG isolated from the urine of pregnant women. An amide column (150 × 2.1 mm, 2.6 μm, 150 A), a mobile phase composed of acetonitrile and water both containing 0.1% of trifluoroacetic acid, and a temperature of 60 °C were used. The gradient was from 85 to 40% ACN in 30 min. The use of TFA that had been shown to be necessary for the separation of glycoforms caused, as expected, an ion suppression effect in MS that was partially overcome by increasing the amount of protein injected (2 μL at 1 mg mL−1) and reducing the detection m/z range (from 1500 to 300). These conditions allowed the detection of different glycoforms of hCGα. The performance of the HILIC-HRMS method was compared with that previously obtained in RPLC-HRMS in terms of the number of detected glycoforms, selectivity, and sensitivity. The complementarity and orthogonality of the HILIC and RP modes for the analysis of hCG at the intact level were demonstrated.

Details

ISSN :
16182650 and 16182642
Volume :
412
Issue :
18
Database :
OpenAIRE
Journal :
Analytical and bioanalytical chemistry
Accession number :
edsair.doi.dedup.....0e666ec8185f1eedce2991913b412f27