Multi-observer comparison study between unenhanced quiescent-interval single-shot magnetic resonance angiography and invasive carbon dioxide angiography in patients with peripheral arterial disease and chronic renal insufficiency

Authors :
Rouben Czwikla
Akos Varga-Szemes
Julian L. Wichmann
Lukas Lenga
Tommaso D'Angelo
Eike Nagel
Axel Thalhammer
Tatjana Gruber-Rouh
Simon S. Martin
Doris Leithner
Christophe T. Arendt
Thomas J. Vogl
Moritz H. Albrecht
Publication Year :
2018
Publisher :
Elsevier, 2018.

Abstract

Non-contrast-enhanced quiescent-interval single-shot magnetic resonance angiography (QISS-MRA) and invasive carbon dioxide (CO2) angiography are suggested as nephroprotective methods for accurate staging of peripheral arterial disease (PAD) in patients with chronic renal insufficiency (CRI). The aim of our study was to compare the image quality of both examinations.16 consecutive PAD patients with highly impaired renal function (estimated glomerular filtration rate (eGFR)30 ml/min/1.73 m²) who underwent 3 T MRA with QISS and catheter angiography with CO2 within 90 days were retrospectively included. Subjective image quality was determined using a five-point Likert scale (1, non-diagnostic; 5, excellent) and presence of significant (≥50%) stenoses of pelvic and lower extremity arteries (21-segment-model) was evaluated per-region and per-segment, respectively, in random order by four independent readers with different levels of experience. CO2 angiography of an experienced interventional radiologist was considered the standard reference method.167 segments were available for direct comparison with a prevalence of ≥50% stenoses of 28.1%. QISS-MRA yield was: sensitivity 91.5%, specificity 94.2%, positive predictive value 86.0% and negative predictive value 96.6%, with an intraclass correlation coeffcient (ICC) of 0.88. Median values of qualitative imaging parameters for QISS-MRA were as follows: arterial signal intensity: 4 (pelvis), 5 (thigh), 5 (calf); venous overlay: 4, 5, 5; susceptibility artifacts: 5, 5, 5; motion artifacts: 4, 5, 5; ECG-related artifacts: 5, 5, 5. ICC-values for image quality were 0.74, 0.73, 0.93, 0.69 and 0.79, respectively. Arterial opacification at CO2 angiography was rated 3, 4, 3, with an ICC of 0.63.Image quality of non-invasive unenhanced MR angiography with QISS was preferred over invasive CO2 angiography, whilst taking into account that it offers high diagnostic performance for the detection and ruling out of PAD.

Details

Language :
English
Database :
OpenAIRE
Accession number :
edsair.doi.dedup.....0e0e122b86ced86aeed867e9809a6e5c