Back to Search
Start Over
Multi-observer comparison study between unenhanced quiescent-interval single-shot magnetic resonance angiography and invasive carbon dioxide angiography in patients with peripheral arterial disease and chronic renal insufficiency
- Publication Year :
- 2018
- Publisher :
- Elsevier, 2018.
-
Abstract
- Non-contrast-enhanced quiescent-interval single-shot magnetic resonance angiography (QISS-MRA) and invasive carbon dioxide (CO2) angiography are suggested as nephroprotective methods for accurate staging of peripheral arterial disease (PAD) in patients with chronic renal insufficiency (CRI). The aim of our study was to compare the image quality of both examinations.16 consecutive PAD patients with highly impaired renal function (estimated glomerular filtration rate (eGFR)30 ml/min/1.73 m²) who underwent 3 T MRA with QISS and catheter angiography with CO2 within 90 days were retrospectively included. Subjective image quality was determined using a five-point Likert scale (1, non-diagnostic; 5, excellent) and presence of significant (≥50%) stenoses of pelvic and lower extremity arteries (21-segment-model) was evaluated per-region and per-segment, respectively, in random order by four independent readers with different levels of experience. CO2 angiography of an experienced interventional radiologist was considered the standard reference method.167 segments were available for direct comparison with a prevalence of ≥50% stenoses of 28.1%. QISS-MRA yield was: sensitivity 91.5%, specificity 94.2%, positive predictive value 86.0% and negative predictive value 96.6%, with an intraclass correlation coeffcient (ICC) of 0.88. Median values of qualitative imaging parameters for QISS-MRA were as follows: arterial signal intensity: 4 (pelvis), 5 (thigh), 5 (calf); venous overlay: 4, 5, 5; susceptibility artifacts: 5, 5, 5; motion artifacts: 4, 5, 5; ECG-related artifacts: 5, 5, 5. ICC-values for image quality were 0.74, 0.73, 0.93, 0.69 and 0.79, respectively. Arterial opacification at CO2 angiography was rated 3, 4, 3, with an ICC of 0.63.Image quality of non-invasive unenhanced MR angiography with QISS was preferred over invasive CO2 angiography, whilst taking into account that it offers high diagnostic performance for the detection and ruling out of PAD.
- Subjects :
- Male
Image quality
Intraclass correlation
Constriction, Pathologic
030204 cardiovascular system & hematology
Thigh
Magnetic resonance angiography
030218 nuclear medicine & medical imaging
0302 clinical medicine
MR-angiography
Prevalence
Medicine
Prospective Studies
TESLA
medicine.diagnostic_test
Angiography
General Medicine
Arteries
Middle Aged
Magnet resonance angiography
Peripheral
medicine.anatomical_structure
Lower Extremity
Nephrogenic systemic fibrosis
Female
Radiology
Adult
Slice-selective QISS
medicine.medical_specialty
Digital subtraction angiography
Renal function
Nutrition examination survey
Sensitivity and Specificity
Lower-extremities
03 medical and health sciences
Peripheral arterial disease
Humans
Radiology, Nuclear Medicine and imaging
Renal Insufficiency, Chronic
Renal insufficiency
Aged
Retrospective Studies
business.industry
Angiography, Digital Subtraction
National-health
Carbon dioxide
Peripheral arterial disease, Renal insufficiency, Magnet resonance angiography, Carbon dioxide, Digital subtraction angiography, Nephrogenic systemic fibrosis, Nutrition examination survey, Slice-selective QISS, MR-angiography, Lower-extremities, National-health, Prevalence, TESLA
business
Magnetic Resonance Angiography
Subjects
Details
- Language :
- English
- Database :
- OpenAIRE
- Accession number :
- edsair.doi.dedup.....0e0e122b86ced86aeed867e9809a6e5c