Back to Search Start Over

Aortic and innominate routes for transcatheter aortic valve implantation

Authors :
Nicolas Mayeur
Nicolas Dumonteil
Olivier Lairez
T. Lhermusier
Thomas Chollet
Jean Porterie
Bertrand Marcheix
Source :
The Journal of Thoracic and Cardiovascular Surgery. 157:1393-1401.e7
Publication Year :
2019
Publisher :
Elsevier BV, 2019.

Abstract

This study aimed at evaluating the efficacy and safety of the transaortic approach for the transcatheter aortic valve implantation procedure using balloon-expandable and self-expanding devices.From January 2012 to December 2016, the transaortic-transcatheter aortic valve implantation procedure was performed in 206 consecutive patients at the Rangueil University Hospital. All procedures were performed by a multidisciplinary heart team. The ascending aorta (27%) or innominate artery (73%) was exposed through a J-type manubriotomy. Events were adjudicated according to Valve Academic Research Consortium-2 criteria.Mean age and logistic European System for Cardiac Risk Evaluation II were 83.9 ± 6.7 years and 16.8% ± 10.8%, respectively. Balloon-expandable and self-expanding valves were implanted in 59.7% and 40.3% of patients, respectively. Device success rate was 98.1%. Thirty-day overall mortality, cardiovascular mortality, cerebrovascular event, myocardial infarction, and permanent pacemaker implantation rates were 5.3%, 4.4%, 1.5%, 1.0%, and 9.7%, respectively (1-year rates: 15.5%, 9.2%, 3.9%, 3.4%, and 10.2%, respectively). Life-threatening bleeding and major vascular complications (7.3% and 3.9%, respectively) were not related to the central access site in approximately half of the cases. Multivariable Cox regression analysis identified preoperative renal failure as an independent predictor of overall mortality (odds ratio, 2.82; 95% confidence interval, 1.73-4.59; P .0001). At the 1-year follow-up, most patients had experienced improved functional status and 98.4% of them were free of moderate to severe paravalvular leak.In a higher-risk subgroup within the patient population receiving transcatheter aortic valve implantation, transaortic-transcatheter aortic valve implantation was successfully performed in 98.1% of cases, with high functional improvement and low rates of mortality and adverse events, especially neurologic complications.

Details

ISSN :
00225223
Volume :
157
Database :
OpenAIRE
Journal :
The Journal of Thoracic and Cardiovascular Surgery
Accession number :
edsair.doi.dedup.....0de91e80aec4d95fa1bd1cdd280d63aa
Full Text :
https://doi.org/10.1016/j.jtcvs.2018.07.098