Back to Search
Start Over
Feasibility of tungsten functional paper in electron grid therapy: a Monte Carlo study
- Source :
- Physics in Medicine and Biology. 62:878-889
- Publication Year :
- 2017
- Publisher :
- IOP Publishing, 2017.
-
Abstract
- Electron grid therapy is expected to be a valid treatment for bulky superficial tumors. It is difficult, however, to fit irradiation fields to bulky superficial tumor shapes for conventional electron grid therapy with a cerrobend grid collimator. In this study, we investigated whether a grid collimator using tungsten functional paper (TFP), with its radiation shielding ability, could be used for electron grid therapy. Dose distributions were measured using 9 MeV electron grid beams from a cerrobend grid collimator. For the simulation study, the same grid irradiation fields were shaped using a TFP grid collimator (thicknesses of 0.15, 0.3, 0.6, 0.9, and 1.2 cm) by laying them on a phantom. We then determined the dose distributions using Monte Carlo calculations and compared the cerrobend and TFP electron grid beams regarding dose distributions, including the depths of the maximum dose (d max), 90% dose (d 90), and 80% dose (d 80), and the ratios of the doses in the areas with and without shielding (valley to peak ratios). The equivalent dosimetric thickness was obtained with the TFP grid collimator that was equivalent to the dose distribution of the cerrobend grid collimator. For the cerrobend electron grid beams, the d max, d 90, and d 80 were 1.0, 2.1, and 2.5 cm, respectively, and the valley to peak ratios at those depths were 0.48, 0.66, and 0.73, respectively. The equivalent dosimetric thickness of TFP was 0.52 cm. The d max, d 90, and d 80 for the 0.52 cm thick TFP electron grid beams were 1.1, 1.9, and 2.3 cm, respectively, and the valley to peak ratios at those depths were 0.49, 0.63, and 0.71, respectively. The TFP grid collimator flexibly delivered excellent dose distributions by simply attaching it to the patient's skin. It could thus be used for electron grid therapy instead of the cerrobend grid collimator.
- Subjects :
- Materials science
genetic structures
Monte Carlo method
chemistry.chemical_element
Electrons
Electron
Tungsten
Imaging phantom
030218 nuclear medicine & medical imaging
law.invention
03 medical and health sciences
0302 clinical medicine
Optics
law
Neoplasms
Humans
Radiology, Nuclear Medicine and imaging
Irradiation
Radiometry
Radiological and Ultrasound Technology
Phantoms, Imaging
business.industry
Radiotherapy Planning, Computer-Assisted
Dose-Response Relationship, Radiation
Collimator
Grid
chemistry
030220 oncology & carcinogenesis
Electromagnetic shielding
Feasibility Studies
business
Monte Carlo Method
Subjects
Details
- ISSN :
- 13616560 and 00319155
- Volume :
- 62
- Database :
- OpenAIRE
- Journal :
- Physics in Medicine and Biology
- Accession number :
- edsair.doi.dedup.....0ca06a270d4b1337f61e44cb9caed7c1