Back to Search
Start Over
Sex-specific 99th percentiles derived from the AACC Universal Sample Bank for the Roche Gen 5 cTnT assay: Comorbidities and statistical methods influence derivation of reference limits
- Source :
- Clinical Biochemistry. 50:1073-1077
- Publication Year :
- 2017
- Publisher :
- Elsevier BV, 2017.
-
Abstract
- Our purpose was to determine a) overall and sex-specific 99th percentile upper reference limits (URL) and b) influences of statistical methods and comorbidities on the URLs.Heparin plasma from 838 normal subjects (423 men, 415 women) were obtained from the AACC (Universal Sample Bank). The cobas e602 measured cTnT (Roche Gen 5 assay); limit of detection (LoD), 3ng/L. Hemoglobin A1c (URL 6.5%), NT-proBNP (URL 125ng/L) and eGFR (60mL/min/1.73m355 men and 339 women remained after exclusions. Overall50% of subjects had measureable concentrations ≥ LoD: 45.6% no exclusion, 43.5% after exclusion; compared to men: 68.1% no exclusion, 65.1% post exclusion; women: 22.7% no exclusion, 20.9% post exclusion. The statistical method used influenced URLs as follows: pre/post exclusion overall, NP 16/16ng/L, HDE 17/17ng/L, R not available; men NP 18/16ng/L, HDE 21/19ng/L, R 16/11ng/L; women NP 13/10ng/L, HDE 14/14ng/L, R not available.We demonstrated that a) the Gen 5 cTnT assay does not meet the IFCC guideline for high-sensitivity assays, b) surrogate biomarkers significantly lowers the URLs and c) statistical methods used impact URLs. Our data suggest lower sex-specific cTnT 99th percentiles than reported in the FDA approved package insert. We emphasize the importance of detailing the criteria used to include and exclude subjects for defining a healthy population and the statistical method used to calculate 99th percentiles and identify outliers.
- Subjects :
- Adult
Male
0301 basic medicine
medicine.medical_specialty
Percentile
media_common.quotation_subject
Clinical Biochemistry
Normal Reference Range
Sample (statistics)
Comorbidity
030204 cardiovascular system & hematology
03 medical and health sciences
Sex Factors
0302 clinical medicine
Troponin T
Troponin complex
Limit of Detection
Reference Values
99th percentile
Internal medicine
Statistics
Humans
Medicine
natural sciences
Normality
Biological Specimen Banks
media_common
Heparin
business.industry
Troponin I
General Medicine
Guideline
Middle Aged
Reference Standards
Sex specific
030104 developmental biology
Biological Assay
Female
business
Biomarkers
Subjects
Details
- ISSN :
- 00099120
- Volume :
- 50
- Database :
- OpenAIRE
- Journal :
- Clinical Biochemistry
- Accession number :
- edsair.doi.dedup.....0b3e1d9514187e2c18fac8c0f94822a6
- Full Text :
- https://doi.org/10.1016/j.clinbiochem.2017.09.009