Back to Search
Start Over
Neutron contamination in radiotherapy: estimation of second cancers based on measurements in 1377 patients
- Source :
- Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology. 107(2)
- Publication Year :
- 2012
-
Abstract
- Purpose Second cancer, as a consequence of a curative intent radiotherapy (RT), represents a growing concern nowadays. The unwanted neutron exposure is an important contributor to this risk in patients irradiated with high energy photon beams. The design and development by our group of a neutron digital detector, together with the methodology to estimate, from the detector readings, the neutron equivalent dose in organs, made possible the unprecedented clinical implementation of an online and systematic neutron dosimetry system. The aim of this study was to systematically estimate neutron equivalent dose in organs of a large patient group treated in different installations. Patients and methods Neutron dosimetry was carried out in 1377 adult patients at more than 30 different institutions using the new neutron digital detector located inside the RT room. Second cancer risk estimates were performed applying ICRP risk coefficients. Results Averaged equivalent dose in organs ranges between 0.5mSv and 129mSv depending on the type of treatment (dose and beam-on time), the distance to isocenter and the linac model. The mean value of the second cancer risk for our patient group is 1.2%. Reference values are proposed for an overall estimation of the risks in 15 linac models (from 2.8×10 −5 to 62.7×10 −5 %/MU). Conclusions The therapeutic benefit of RT must outweigh the second cancer risk. Thus, these results should be taken into account when taking clinical decisions regarding treatment strategy choice during RT planning.
- Subjects :
- Adult
Male
medicine.medical_specialty
medicine.medical_treatment
Neutron contamination
Neoplasms
Medicine
Humans
Radiology, Nuclear Medicine and imaging
Neutron
Medical physics
Estimation
Neutrons
business.industry
Equivalent dose
Detector
Isocenter
Second cancer
Neoplasms, Second Primary
Radiotherapy Dosage
Hematology
Radiation therapy
Oncology
Female
business
Nuclear medicine
Subjects
Details
- ISSN :
- 18790887
- Volume :
- 107
- Issue :
- 2
- Database :
- OpenAIRE
- Journal :
- Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology
- Accession number :
- edsair.doi.dedup.....0ad663180cb1c37ab5e9fcd82aafdf71