Back to Search Start Over

The valve uptake index: improving assessment of prosthetic valve endocarditis and updating [18F]FDG PET/CT(A) imaging criteria

Authors :
Albert Roque
María N Pizzi
Nuria Fernández-Hidalgo
Guillermo Romero-Farina
Gemma Burcet
José Luis Reyes-Juarez
Carina Espinet
Joan Castell-Conesa
Manuel Escobar
Ignacio Ferreira-González
Santiago Aguadé-Bruix
Hug Cuellar-Calabria
Institut Català de la Salut
[Roque A, Burcet G, Reyes-Juarez JL, Cuellar-Calabria H] Servei de Radiologia, Vall d’Hebron Hospital Universitari, Barcelona, Spain. IDI (Institut de Diagnòstic per la Imatge), Barcelona, Spain. Departament de Medicina, Universitat Autònoma de Barcelona, Bellaterra, Spain. Vall d’Hebron Institut de Recerca (VHIR), Barcelona, Spain. [Pizzi MN] Departament de Medicina, Universitat Autònoma de Barcelona, Bellaterra, Spain. Vall d’Hebron Institut de Recerca (VHIR), Barcelona, Spain. Servei de Cardiologia, Vall d’Hebron Hospital Universitari, Barcelona, Spain. Centro de Investigación Biomedica en Red en Enfermedades Cardiovasculares (CIBERCV), Madrid, Spain. [Fernández-Hidalgo N] Departament de Medicina, Universitat Autònoma de Barcelona, Bellaterra, Spain. Vall d’Hebron Institut de Recerca (VHIR), Barcelona, Spain. Servei de Malalties Infeccioses, Vall d’Hebron Hospital Universitari, Barcelona, Spain. [Romero-Farina G] Vall d’Hebron Institut de Recerca (VHIR), Barcelona, Spain. Servei de Cardiologia, Vall d’Hebron Hospital Universitari, Barcelona, Spain. [Espinet C, Castell-Conesa J] IDI (Institut de Diagnòstic per la Imatge), Barcelona, Spain. Departament de Medicina, Universitat Autònoma de Barcelona, Bellaterra, Spain. Servei de Medicina Nuclear, Vall d’Hebron Hospital Universitari, Barcelona, Spain. [Escobar M] Servei de Radiologia, Vall d’Hebron Hospital Universitari, Barcelona, Spain. IDI (Institut de Diagnòstic per la Imatge), Barcelona, Spain. [Ferreira-González I] Departament de Medicina, Universitat Autònoma de Barcelona, Bellaterra, Spain. Servei de Cardiologia, Vall d’Hebron Hospital Universitari, Barcelona, Spain. CIBER de Epidemiologıa y Salud Pública (CIBERESP), Madrid, Spain. [Aguadé-Bruix S] Departament de Medicina, Universitat Autònoma de Barcelona, Bellaterra, Spain. Vall d’Hebron Institut de Recerca (VHIR), Barcelona, Spain. Centro de Investigación Biomedica en Red en Enfermedades Cardiovasculares (CIBERCV), Madrid, Spain. Servei de Medicina Nuclear, Vall d’Hebron Hospital Universitari, Barcelona, Spain
Vall d'Hebron Barcelona Hospital Campus
Source :
Scientia
Publication Year :
2021

Abstract

Aims Diagnosis of prosthetic valve endocarditis (PVE) by positron emission computed tomography angiography (PET/CTA) is based on visual and quantitative morpho-metabolic features. However, the fluorodeoxyglucose (FDG) uptake pattern can be sometimes visually unclear and susceptible to subjectivity. This study aimed to validate a new parameter, the valve uptake index [VUI, maximum standardized uptake value (SUVmax)−mean standardized uptake value (SUVmean)/SUVmax], designed to provide a more objective indication of the distribution of metabolic activity. Secondly, to re-evaluate the utility of traditionally used PVE imaging criteria and determine the potential value of adding the VUI in the diagnostic algorithm of PVE. Methods and results Retrospective analysis of 122 patients (135 prosthetic valves) admitted for suspicion of endocarditis, with a conclusive diagnosis of definite (N = 57) or rejected (N = 65) PVE, and who had undergone a cardiac PET/CTA scan as part of the diagnostic evaluation. We measured the VUI and recorded the SUVmax, SUVratio, uptake pattern, and the presence of endocarditis-related anatomic lesions. The VUI, SUVmax, and SUVratio values were 0.54 ± 0.1 vs. 0.36 ± 0.08, 7.68 ± 3.07 vs. 3.72 ± 1.11, and 4.28 ± 1.93 vs. 2.16 ± 0.95 in the ‘definite’ PVE group vs. the ‘rejected’ group, respectively (mean ± SD; P < 0.001). A cut-off value of VUI > 0.45 showed a sensitivity, specificity, and diagnostic accuracy for PVE of 85%, 88%, and 86.7% and increased diagnostic ability for confirming endocarditis when combined with the standard diagnostic criteria. Conclusions The VUI demonstrated good diagnostic accuracy for PVE, even increasing the diagnostic power of the traditionally used morphometabolic parameters, which also confirmed their own diagnostic performance. More research is needed to assess whether the integration of the VUI into the PVE diagnostic algorithm may clarify doubtful cases and thus improve the diagnostic yield of PET/CTA.

Details

ISSN :
20472412
Volume :
23
Issue :
9
Database :
OpenAIRE
Journal :
European heart journal. Cardiovascular Imaging
Accession number :
edsair.doi.dedup.....0a8c0372b04160dcd2cf987ba4de4b46