Back to Search
Start Over
A case report of progressive obstruction of Ex-PRESS miniature glaucoma shunt after transient flat anterior chamber and treatment using Nd:YAG laser
- Source :
- BMC Ophthalmology
- Publication Year :
- 2015
- Publisher :
- BioMed Central, 2015.
-
Abstract
- Background We report a case of Ex-PRESS miniature glaucoma shunt obstruction resulting from progressive iris synechial formation after transient anterior chamber shallowing. Case presentation A 68-year-old woman with pseudoexfoliation glaucoma in her right eye underwent filtration surgery with implantation of the Ex-PPESS shunt (model P-50, Alcon Japan, Tokyo, Japan) in combination with intra-surgical 0.04% mitomycin C use. After the anterior chamber injection of viscoelastic material and 100% sulfur hexafluoride gas for treatment of early postoperative over filtration, the intraocular pressure (IOP) was controlled between 9 and 12 mmHg. On postoperative day 121, gonioscopy showed that synechial formation around the shunt obstructed the axial port leaving the relief port opened. On postoperative day 274, the intraocular pressure increased to 40 mmHg and synechiae obstructed both the axial and relief ports. Dispersion of iris tissue by neodymium:yttrium-aluminium-garnet (Nd:YAG) laser (2 mJ, one shot to each port) opened both ports and immediately lowered the IOP, leaving peripheral anterior synechiae around the shunt. Up to postoperative day 400, the IOP was controlled between 13 and 15 mmHg, and the cystic bleb was maintained. Conclusion The synechiae formed gradually extends around the shunt’s shaft and can result in later external obstruction of the relief port. The current case requires further follow-up since synechiae remaining around the shaft can cause future obstruction. We emphasize the fact that, if the iris synechiae to the shunt once formed, it can progress and obstruct the shunt ports later.
- Subjects :
- medicine.medical_specialty
Intraocular pressure
genetic structures
Flat anterior chamber
Anterior Chamber
medicine.medical_treatment
Glaucoma
Case Report
Lasers, Solid-State
Progressive obstruction
Trabeculectomy, Surgical complication
Ex-PRESS miniature glaucoma shunt
Trabeculectomy
Surgical complication
Hypotony
Neodymium:yttrium-aluminium-garnet (Nd:YAG) laser
Postoperative Complications
Ophthalmology
Gonioscopy
Glaucoma surgery
Medicine
Humans
Glaucoma Drainage Implants
Aged
medicine.diagnostic_test
business.industry
General Medicine
medicine.disease
eye diseases
Surgery
Shunt (medical)
Treatment Outcome
Nd:YAG laser
Filtering Surgery
Equipment Failure
Female
business
Subjects
Details
- Language :
- English
- ISSN :
- 14712415
- Volume :
- 15
- Database :
- OpenAIRE
- Journal :
- BMC Ophthalmology
- Accession number :
- edsair.doi.dedup.....0a59e4ca5c3cc41a72636f8cfe879f97