Back to Search
Start Over
An improvement of separation and response applying post-column compensation and one-step acetone protein precipitation for the determination of coenzyme Q10 in rat plasma by SFC-MS/MS
- Source :
- Journal of chromatography. B, Analytical technologies in the biomedical and life sciences. 1031
- Publication Year :
- 2016
-
Abstract
- Coenzyme Q10 (CoQ10) solid dispersion was prepared to improve its oral bioavailability due to the poor solubility of CoQ10. To evaluate the pharmacokinetic behaviors of CoQ10 solid dispersion, a simple, rapid, sensitive and environment friendly method for the determination of CoQ10 in rat plasma was developed. In this study, samples were prepared by one-step protein precipitation with acetone and then the supercritical fluid chromatography-electrospray ionization tandem mass spectrometry (SFC-ESI-MS/MS) method was used. The separation was achieved by an ACQUITY UPC(2)™ BEH 2-EP column (100mm×3mm, 1.7μm) maintained at 35°C, using carbon dioxide (≥99.99%) and methanol (85:15, v/v) as the mobile phase at a flow rate of 1.0ml/min. To improve the response and sensitivity, the compensation solvent of methanol with 2mM ammonium acetate at a flow rate of 0.2ml/min was used and the total analysis time was only 1.5min for each sample. The detection was carried out on a tandem mass spectrometer with electrospray ionization (ESI) source and the mass transition ion pair was m/z 881.0→197.0 and 285.1→193.0 for CoQ10 and diazepam, internal standard (IS), respectively. Calibration curve was linear over the concentration range of 2.00-500.00ng/ml (r(2)≥0.998) with a lower limit of quantification of 2.00ng/ml. The intra- and inter-day accuracy and precision were below 15% for all quality control samples. The proposed method was rapid, accurate and reproducible, which was suitable to compare the pharmacokinetic behaviors in rats after a single oral dose of 100mg/kg CoQ10 solid dispersion or tablets.
- Subjects :
- Male
Calibration curve
Ubiquinone
Electrospray ionization
Clinical Biochemistry
Analytical chemistry
Mass spectrometry
Tandem mass spectrometry
030226 pharmacology & pharmacy
01 natural sciences
Biochemistry
Analytical Chemistry
Acetone
03 medical and health sciences
chemistry.chemical_compound
0302 clinical medicine
Tandem Mass Spectrometry
Protein precipitation
Animals
Solubility
Chromatography
010401 analytical chemistry
Reproducibility of Results
Cell Biology
General Medicine
0104 chemical sciences
Rats
chemistry
Dispersion (chemistry)
Ammonium acetate
Subjects
Details
- ISSN :
- 1873376X
- Volume :
- 1031
- Database :
- OpenAIRE
- Journal :
- Journal of chromatography. B, Analytical technologies in the biomedical and life sciences
- Accession number :
- edsair.doi.dedup.....0a5093becfa5c174730a4768b5051973