Back to Search
Start Over
Calibration of Raman lidar water vapor mixing ratio measurements using zenithal measurements of diffuse sunlight and a radiative transfer model
- Source :
- UPCommons. Portal del coneixement obert de la UPC, Universitat Politècnica de Catalunya (UPC), IEEE Transactions on Geoscience and Remote Sensing
- Publication Year :
- 2018
- Publisher :
- Institute of Electrical and Electronics Engineers (IEEE), 2018.
-
Abstract
- This is a postprint (author final draft) version of article that has been accepted for publication. A fully version can be found at: https://doi.org/10.1109/TGRS.2018.2851064 © 2018 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works. Among the different techniques available for measuring the atmospheric water vapor content, Raman lidars stand out as accurate instruments providing detailed profiles with high temporal and altitude resolution. Their principle is based on obtaining the range-resolved ratio of the lidar signals corresponding to Raman returns from water vapor and nitrogen molecules, which is proportional to the water vapor mixing ratio. To do this, it is necessary to determine a calibration factor, specific of each lidar instrument. A method for obtaining this parameter, based on zenith measurements of diffuse sunlight, on Raman scattering models and on simulations, using a radiative transfer model, to estimate sky radiances at the wavelengths of interest, has been applied to the lidar system of Universitat Politècnica de Catalunya (UPC; Technical University of Catalonia, Barcelona, Spain). A set of calibrations, performed between 2016 and 2017, has permitted assessing the calibration procedure and analyzing the stability of the calibration factor in the UPC instrument. Results show that although the calibration factor can remain stable for long periods of time, it can suffer sudden variations that make indispensable to implement a convenient and reliable procedure to perform regular calibrations. We show that the method, which can be applied to any lidar with water vapor and nitrogen Raman channels, can completely dispense with radiosonde data. The calibration method is validated by comparison with simultaneous radiosonde water vapor measurements. Limitations of radiosondes for validating--and eventually calibrating--water vapor Raman lidars have been revealed.
- Subjects :
- 010504 meteorology & atmospheric sciences
Enginyeria de la telecomunicació::Radiocomunicació i exploració electromagnètica::Radar [Àrees temàtiques de la UPC]
Atmospheric model
01 natural sciences
Atmospheric measurements
law.invention
010309 optics
symbols.namesake
Atmospheric radiative transfer codes
law
0103 physical sciences
Calibration
Electrical and Electronic Engineering
Raman
0105 earth and related environmental sciences
Remote sensing
Water vapor
Lidar
Làsers
Enginyeria electrònica::Optoelectrònica::Làser [Àrees temàtiques de la UPC]
Radar
Lasers
Laser radar
symbols
Radiosonde
General Earth and Planetary Sciences
Environmental science
Raman spectroscopy
Raman scattering
Subjects
Details
- Language :
- English
- Database :
- OpenAIRE
- Journal :
- UPCommons. Portal del coneixement obert de la UPC, Universitat Politècnica de Catalunya (UPC), IEEE Transactions on Geoscience and Remote Sensing
- Accession number :
- edsair.doi.dedup.....08c1bc3fc14ad902e1491a01d1694745