Back to Search
Start Over
Graph-based risk assessment and error detection in radiation therapy
- Source :
- Medical physicsREFERENCES. 48(3)
- Publication Year :
- 2020
-
Abstract
- PURPOSE The objective of this study was to formalize and automate quality assurance (QA) in radiation oncology. Quality assurance in radiation oncology entails a multistep verification of complex, personalized radiation plans to treat cancer involving an interdisciplinary team and high technology, multivendor software and hardware systems. We addressed the pretreatment physics chart review (TPCR) using methods from graph theory and constraint programming to study the effect of dependencies between variables and automatically identify logical inconsistencies and how they propagate. MATERIALS AND METHODS We used a modular approach to decompose the TPCR process into tractable units comprising subprocesses, modules and variables. Modules represented the main software entities comprised in the radiation treatment planning workflow and subprocesses grouped the checks to be performed by functionality. Module-associated variables served as inputs to the subprocesses. Relationships between variables were modeled by means of a directed graph. The detection of errors, in the form of inconsistencies, was formalized as a constraint satisfaction problem whereby checks were encoded as logical formulae. The sequence in which subprocesses were visited was described in an activity diagram. RESULTS The comprehensive model for the TPCR process comprised 5 modules, 19 subprocesses and 346 variables, 225 of which were distinct. Modules included "Treatment Planning System" and "Record and Verify System." Subprocesses included "Dose Prescription," "Documents," "CT Integrity," "Anatomical Contours," "Beam Configuration," "Dose Calculation," "3D Dose Distribution Quality," and "Treatment Approval." Variable inconsistencies, and their source and propagation were determined by checking for constraint violation and through graph traversal. Impact scores, obtained through graph traversal, combined with severity scores associated with an inconsistency, allowed risk assessment. CONCLUSIONS Directed graphs combined with constraint programming hold promise for formalizing complex QA processes in radiation oncology, performing risk assessment and automating the TPCR process. Though complex, the process is tractable.
- Subjects :
- QA75
RM
Theoretical computer science
Quality Assurance, Health Care
QA75 Electronic computers. Computer science
Risk Assessment
030218 nuclear medicine & medical imaging
Workflow
RC0254
03 medical and health sciences
0302 clinical medicine
Software
SDG 3 - Good Health and Well-being
Graph traversal
Constraint programming
Humans
Automated checks
Physics chart review
Constraint satisfaction problem
Risk assessment
RC0254 Neoplasms. Tumors. Oncology (including Cancer)
business.industry
Radiotherapy Planning, Computer-Assisted
Graph theory
Radiotherapy Dosage
3rd-DAS
General Medicine
Directed graph
Modular design
RM Therapeutics. Pharmacology
030220 oncology & carcinogenesis
Radiation Oncology
business
Graphs
Quality assurance
Model
Subjects
Details
- ISSN :
- 24734209
- Volume :
- 48
- Issue :
- 3
- Database :
- OpenAIRE
- Journal :
- Medical physicsREFERENCES
- Accession number :
- edsair.doi.dedup.....081239a2bfba744ad69dc040f7dda01b