Back to Search
Start Over
Monte Carlo calculation of monoenergetic and polyenergetic DgN coefficients for mean glandular dose estimates in mammography using a homogeneous breast model
- Source :
- Physics in Medicine & Biology. 64:125012
- Publication Year :
- 2019
- Publisher :
- IOP Publishing, 2019.
-
Abstract
- We computed normalized glandular dose (DgN) coefficients for mean glandular dose estimates in contemporary 2D mammography units, taking into account a realistic homogeneous model for the breast. We developed a Monte Carlo code based on the simulation toolkit GEANT4 ver. 10.00. The breast was modelled as a cylinder with a semi-cylindrical section with a radius of 10 cm, enveloped in a 1.45-mm thick skin layer, as found out in recent reports from the University of California Davis team in the analysis of breast computed tomography clinical scans. The compressed breast thickness was between 3 cm and 8 cm. The DgN coefficients were calculated for monoenergetic X-ray beams between 4.25 keV and 49.25 keV and were fitted with polynomial curves. Polyenergetic DgN coefficients were then computed for spectra obtained for various anode/filter combinations as adopted in routine clinical practice: Mo/Mo 30 μm (2540 kV), Mo/Rh 25 μm (2540 kV), Rh/Rh 25 μm (2540 kV), W/Ag 50 μm (2634 kV), W/Al 500 μm (2638 kV), W/Al 700 μm (2840 kV) and W/Rh 50 μm (2435 kV). Monoenergetic DgN curve fit coefficients and polyenergetic DgNp coefficients were released for research and clinical work. Polyenergetic DgN coefficients were 6% higher than those provided in the reference literature, on average. The differences ranges between -18% and 30%; 50% of the computed coefficients differed by less than 10%. The dataset of DgN coefficients are provided as tables (49 pages) for varying glandular fraction by mass and compressed breast thickness. Moreover, a computer code has been developed for generating user specific coefficients DgNp for user defined X-ray spectra up to 49 kV, calculated by spectral weighting from the dataset of monoenergetic DgN coefficients.
- Subjects :
- mean glandular dose
Polynomial curves
Materials science
mammography
DgN
Monte Carlo method
Computed tomography
Radiation Dosage
030218 nuclear medicine & medical imaging
03 medical and health sciences
0302 clinical medicine
medicine
Humans
Mammography
Radiology, Nuclear Medicine and imaging
Breast
Geant 4 simulation
Radiological and Ultrasound Technology
medicine.diagnostic_test
Radius
Computational physics
Homogeneous
030220 oncology & carcinogenesis
Curve fitting
Thick skin
Female
Tomography, X-Ray Computed
Monte Carlo Method
Algorithms
Subjects
Details
- ISSN :
- 13616560
- Volume :
- 64
- Database :
- OpenAIRE
- Journal :
- Physics in Medicine & Biology
- Accession number :
- edsair.doi.dedup.....07e247fe47158ae4be9ca051243b4bc3
- Full Text :
- https://doi.org/10.1088/1361-6560/ab253f