Back to Search
Start Over
Optimum screening mammography reading volumes: evidence from the NHS Breast Screening Programme
- Source :
- European Radiology. 31:6909-6915
- Publication Year :
- 2021
- Publisher :
- Springer Science and Business Media LLC, 2021.
-
Abstract
- Minimum caseload standards for professionals examining breast screening mammograms vary from 480 (US) to 5000 (Europe). We measured the relationship between the number of women’s mammograms examined per year and reader performance. We extracted routine records from the English NHS Breast Screening Programme for readers examining between 1000 and 45,000 mammograms between April 2014 and March 2017. We measured the relationship between the volume of cases read and screening performance (cancer detection rate, recall rate, positive predictive value of recall (PPV) and discrepant cancers) using linear logistic regression. We also examined the effect of reader occupational group on performance. In total, 759 eligible mammography readers (445 consultant radiologists, 235 radiography advanced practitioners, 79 consultant radiographers) examined 6.1 million women’s mammograms during the study period. PPV increased from 12.9 to 14.4 to 17.0% for readers examining 2000, 5000 and 10000 cases per year respectively. This was driven by decreases in recall rates from 5.8 to 5.3 to 4.5 with increasing volume read, and no change in cancer detection rate (from 7.6 to 7.6 to 7.7). There was no difference in cancer detection rate with reader occupational group. Consultant radiographers had higher recall rate and lower PPV compared to radiologists (OR 1.105, p = 0.012; OR 0.874, p = 0.002, unadjusted). Positive predictive value of screening increases with the total volume of cases examined per reader, through decreases in numbers of cases recalled with no concurrent change in numbers of cancers detected. • In the English Breast Screening Programme, readers who examined a larger number of cases per year had a higher positive predictive value, because they recalled fewer women for further tests but detected the same number of cancers. • Reader type did not affect cancer detection rate, but consultant radiographers had a higher recall rate and lower positive predictive value than consultant radiologists, although this was not adjusted for length of experience.
- Subjects :
- medicine.medical_specialty
media_common.quotation_subject
Radiography
Breast Neoplasms
Logistic regression
Sensitivity and Specificity
State Medicine
Breast cancer
Reading (process)
medicine
Humans
Mass Screening
Mammography
Breast screening
Radiology, Nuclear Medicine and imaging
Early Detection of Cancer
Mass screening
media_common
Recall
medicine.diagnostic_test
Obstetrics
business.industry
General Medicine
medicine.disease
Female
Radiology
RG
business
RA
RC
Subjects
Details
- ISSN :
- 14321084 and 09387994
- Volume :
- 31
- Database :
- OpenAIRE
- Journal :
- European Radiology
- Accession number :
- edsair.doi.dedup.....05b4e10ebb42fb1fc152a4da8770374c
- Full Text :
- https://doi.org/10.1007/s00330-021-07754-8