Back to Search
Start Over
Obtaining optimum screw placement for revision acetabular prostheses using the sciatic notch as reference
- Source :
- Translational Research in Anatomy, Vol 24, Iss, Pp 100133-(2021)
- Publication Year :
- 2021
- Publisher :
- Elsevier, 2021.
-
Abstract
- Background The use of transacetabular screws aid greatly in attaining acetabular component stability during acetabular revision surgery. There are, however, definite risks involved when using this technique. Inserting screws in the posterior superior safe zone has been advocated as a way to do this safely, but recent studies have shown that this does not hold true in conditions where acetabular anatomy is distorted or where the hip centre of rotation has moved. A method to insert these screws more accurately and safely is proposed. Questions/Purposes (1) Can using the greater sciatic notch as reference point when inserting transacetabular screws for revision acetabular cups ensure accurate and safe placement of screws? (2) How does this proposed new method compare with the posterior superior safe zone method? Methods With the use of an observational anatomic study we have developed a new method for the insertion of long transacetabular screws. This method uses the greater sciatic notch as a reference point. Our method was tested on 16 cadaveric hips (reamed to simulate revision conditions) and compared to the safe zone method. Results Our method achieved placement of 1–3 screws in the target area in all hips without penetration into the pelvis or sciatic notch. With the use of the safe zone only as reference the pelvis was penetrated 7 times and the sciatic notch twice. Conclusion Using the greater sciatic notch as a reference guide enables the surgeon to engage a supportive bar of bone for one or more long home run screws whilst minimizing penetration of the pelvis and sciatic notch. In this study our method was superior to using the safe zone in isolation.
- Subjects :
- Orthodontics
musculoskeletal diseases
Insert (composites)
business.industry
Sciatic notch
QM1-695
equipment and supplies
musculoskeletal system
Revision hip arthroplasty
Greater sciatic notch
Screw placement
Safe zone
Centre of rotation
medicine.anatomical_structure
surgical procedures, operative
Acetabular component
Human anatomy
medicine
Transacetabular screw
Anatomy
business
Cadaveric spasm
Pelvis
Acetabular revision
Subjects
Details
- Language :
- English
- Volume :
- 24
- Database :
- OpenAIRE
- Journal :
- Translational Research in Anatomy
- Accession number :