Back to Search Start Over

Transplantation of declined livers after normothermic perfusion

Authors :
Cristiano Quintini
Luca Del Prete
Andrea Simioni
Laurent Del Angel
Teresa Diago Uso
Giuseppe D’Amico
Koji Hashimoto
Federico Aucejo
Masato Fujiki
Bijan Eghtesad
Kazunari Sasaki
Choon Hyuck David Kwon
Jacek Cywinski
Ana Bennett
Mary Bilancini
Charles Miller
Qiang Liu
Source :
Surgery. 171:747-756
Publication Year :
2022
Publisher :
Elsevier BV, 2022.

Abstract

The persistent shortage of liver allografts contributes to significant waitlist mortality despite efforts to increase organ donation. Normothermic machine perfusion holds the potential to enhance graft preservation, extend viability, and allow liver function evaluation in organs previously discarded because considered too high-risk for transplant.Discarded livers from other transplant centers were transplanted after assessment and reconditioning with our institutionally developed normothermic machine perfusion device. We report here our preliminary data.Twenty-one human livers declined for transplantation were enrolled for assessment with normothermic machine perfusion. Six livers (28.5%) were ultimately discarded after normothermic machine perfusion because of insufficient lactate clearance (4.1 mmol/L after 4 hours), limited bile production (0.5 mI/h), or moderate macrosteatosis, whereas 15 (71.5%) were considered suitable for transplantation. Normothermic machine perfusion duration was from 3 hours, 49 minutes to 10 hours, 29 minutes without technical problems or adverse events. No intraoperative or major early postoperative complications occurred in all transplanted recipients. No primary nonfunction occurred after transplantation. Seven livers had early allograft dysfunction with fast recovery, and 1 patient developed ischemic cholangiopathy after 4 months treated with biliary stents. All other patients had good liver function with a follow-up time of 8 weeks to 14 months.In total, 71.5% of discarded livers subjected to ex vivo normothermic machine perfusion were successfully transplanted after organ perfusion and assessment using an institutionally built device. This study challenges the current viability criteria reported in the literature and calls for a standardization of viability markers collection, an essential condition for the advancement of the field.

Details

ISSN :
00396060
Volume :
171
Database :
OpenAIRE
Journal :
Surgery
Accession number :
edsair.doi.dedup.....03cb4bf62f5dcdfd4754eac541d5da60
Full Text :
https://doi.org/10.1016/j.surg.2021.10.056