Back to Search Start Over

Minimally invasive plate osteosynthesis and vascularity: preliminary results of a cadaver injection study

Authors :
Theodore Miclau
Christian Krettek
Osama Farouk
Peter Schandelmaier
H. Tscherne
Pierre Guy
Source :
Scopus-Elsevier
Publication Year :
1997

Abstract

A cadaver arterial injection study was performed to analyse the vascular supply to the femur and to study the effects of two surgical plating techniques on femoral vascularity. A 16-hole LC-DCP was applied on the intact femora of five fresh human cadavers. On one side, the plate was inserted using a conventional lateral plate osteosynthesis (CLPO) technique with elevation of the vastus lateralis muscle to expose the shaft. On the contralateral side, the plate was inserted percutaneously beneath the muscle using a minimally invasive plate osteosynthesis (MIPO) technique. After plating, blue silicone dye was injected through the common femoral artery. Cadaveric dissection was then performed to identify the femoral perforating arteries (PAs) and the nutrient artery (NA) of the femur. The pattern of periosteal filling and medullary perfusion of the injected dye was analysed and the topography of the PAs and NA was determined. CLPO placed the PAs and NA of the femur at risk. MIPO maintained the integrity of the PAs and NA and was associated with superior periosteal and medullary perfusion. The results of this study indicate that MIPO is superior to the CLPO in maintaining arterial femoral vascularity and perfusion.

Details

ISSN :
00201383
Volume :
28
Database :
OpenAIRE
Journal :
Injury
Accession number :
edsair.doi.dedup.....0398efdac560e27250d3abec2f9b6c86