Back to Search
Start Over
Addressing Artificial Intelligence Bias in Retinal Diagnostics
- Source :
- Translational Vision Science & Technology
- Publication Year :
- 2021
- Publisher :
- Association for Research in Vision and Ophthalmology (ARVO), 2021.
-
Abstract
- Purpose This study evaluated generative methods to potentially mitigate artificial intelligence (AI) bias when diagnosing diabetic retinopathy (DR) resulting from training data imbalance or domain generalization, which occurs when deep learning systems (DLSs) face concepts at test/inference time they were not initially trained on. Methods The public domain Kaggle EyePACS dataset (88,692 fundi and 44,346 individuals, originally diverse for ethnicity) was modified by adding clinician-annotated labels and constructing an artificial scenario of data imbalance and domain generalization by disallowing training (but not testing) exemplars for images of retinas with DR warranting referral (DR-referable) from darker-skin individuals, who presumably have greater concentration of melanin within uveal melanocytes, on average, contributing to retinal image pigmentation. A traditional/baseline diagnostic DLS was compared against new DLSs that would use training data augmented via generative models for debiasing. Results Accuracy (95% confidence intervals [CIs]) of the baseline diagnostics DLS for fundus images of lighter-skin individuals was 73.0% (66.9% to 79.2%) versus darker-skin of 60.5% (53.5% to 67.3%), demonstrating bias/disparity (delta = 12.5%; Welch t-test t = 2.670, P = 0.008) in AI performance across protected subpopulations. Using novel generative methods for addressing missing subpopulation training data (DR-referable darker-skin) achieved instead accuracy, for lighter-skin, of 72.0% (65.8% to 78.2%), and for darker-skin, of 71.5% (65.2% to 77.8%), demonstrating closer parity (delta = 0.5%) in accuracy across subpopulations (Welch t-test t = 0.111, P = 0.912). Conclusions Findings illustrate how data imbalance and domain generalization can lead to disparity of accuracy across subpopulations, and show that novel generative methods of synthetic fundus images may play a role for debiasing AI. Translational relevance New AI methods have possible applications to address potential AI bias in DR diagnostics from fundus pigmentation, and potentially other ophthalmic DLSs too.
- Subjects :
- 0301 basic medicine
Fundus Oculi
Generalization
Computer science
Biomedical Engineering
Inference
Debiasing
Fundus (eye)
Retina
Article
03 medical and health sciences
chemistry.chemical_compound
0302 clinical medicine
Humans
Mass Screening
automated diagnostics
Mass screening
business.industry
Deep learning
deep learning
Retinal
artificial intelligence
Confidence interval
diabetic retinopathy
Ophthalmology
030104 developmental biology
chemistry
030221 ophthalmology & optometry
Artificial intelligence
business
Subjects
Details
- ISSN :
- 21642591
- Volume :
- 10
- Database :
- OpenAIRE
- Journal :
- Translational Vision Science & Technology
- Accession number :
- edsair.doi.dedup.....00cb7f19a1b4e4e1ce45b6aea3a5d103