Back to Search Start Over

First magnifying neutron/x-ray combined radiography at Shenguang laser facility

Authors :
J. J. Li
B. Yu
T. Xu
Z. J. Chen
J. H. Zheng
L. Yao
Y. S. Dong
J. M. Yang
Source :
AIP Advances. 12:115012
Publication Year :
2022
Publisher :
AIP Publishing, 2022.

Abstract

Neutron/x-ray combined radiography can integrate the merits of x-ray and neutron radiography and have an enhanced non-destructive detecting capability compared to single neutron or x-ray radiography. In this work, magnifying neutron/x-ray combined radiography along the same line of sight was performed at the Shenguang (SG) laser facility for the first time. Based on [Formula: see text] mm point-like backlight sources of neutrons and x rays, structural defects on the order of ∼0.2 mm within polyethylene and Fe were observed in neutron and x-ray radiography, respectively. In addition, the spatial resolution obtained was 0.68 ∼ 2.05 mm in the object position for neutron radiography and ∼0.14 mm for x-ray radiography. This indicated that the combined radiography system arranged along the same line of sight at the SG laser facility possessed the ability to inspect structural defects within both low-Z and high-Z materials simultaneously, with relatively high spatial resolution.

Subjects

Subjects :
General Physics and Astronomy

Details

ISSN :
21583226
Volume :
12
Database :
OpenAIRE
Journal :
AIP Advances
Accession number :
edsair.doi...........fd0ee07f1cda2a5082f814af564d8611