Back to Search
Start Over
Failure analysis of fine Cu patterning by shave-off profiling
- Source :
- Surface and Interface Analysis. 43:621-624
- Publication Year :
- 2010
- Publisher :
- Wiley, 2010.
-
Abstract
- We focused on failure within fine copper patterning on a semiconductor chip. Three grades of samples were prepared; hard CMP treatment, soft CMP treatment and standard, and compared the differences by shave-off profiling. The shave-off profiles of CMP treatment revealed a saw-toothed structure, and the shave-off profile of a standard chip was revealed as a periodic triangular wave. The difference can be explained by the existence of residue on the CMP process. Copyright © 2010 John Wiley & Sons, Ltd.
Details
- ISSN :
- 01422421
- Volume :
- 43
- Database :
- OpenAIRE
- Journal :
- Surface and Interface Analysis
- Accession number :
- edsair.doi...........fcbba8fdbc7d51b9e43172c0dddba2aa
- Full Text :
- https://doi.org/10.1002/sia.3396