Abstract

This article presents the performance analysis of a 2.2 kW p photovoltaic system installed at the State University of Ceara, Fortaleza, Brazil (latitude 3.40°S, longitude 38.33°W and 31 m above sea level). The system was monitored from June 2013 to May 2014. In the measured period the annual energy yield was 1685.5 kWh/kW p . The average daily reference, array and final yields of the system were 5.6 kWh/kW p , 4.9 kWh/kW p and 4.6 kWh/kW p , respectively. The annual average daily array and system losses were 1.05 kWh/kW p and the annual average array, system and inverter efficiencies were 13.3%, 12.6% and 94.6%, respectively. The performance ratio and capacity factor were 82.9% and 19.2%, respectively. These numbers highlight the relatively good performance of PV systems installed in the northeast region of Brazil.

Details

ISSN :
09730826
Volume :
37
Database :
OpenAIRE
Journal :
Energy for Sustainable Development
Accession number :
edsair.doi...........fbfebd137da45b594e676b345b7a619d
Full Text :
https://doi.org/10.1016/j.esd.2017.01.004