Back to Search Start Over

Failure Analysis on Fracture of a 3-1/2″ P110SS Tubing

Authors :
Guan Fa Lin
R. Cai
Juan Tao Zhang
Xue Hui Zhao
Yan Han
Source :
Advanced Materials Research. :1412-1417
Publication Year :
2012
Publisher :
Trans Tech Publications, Ltd., 2012.

Abstract

The tubing, as a key ingredient in the well development, worked always under very complex stress and corrosion conditions, the failure of the tubing could cause huge losses. In this paper, a fractured 3-1/2″ P110SS tubing was analyzed through physical and chemical properties testing, SEM, EDS, and XRD method. The results showed that the failure of the tubing was belong to hydrogen sulfide stress corrosion cracking. The tubing material could not pass the SSC test, it was inappropriate to use in well contained high hydrogen sulfide.

Details

ISSN :
16628985
Database :
OpenAIRE
Journal :
Advanced Materials Research
Accession number :
edsair.doi...........f421ab7470aa7e2a48470448ad2cf267