Abstract
- It is difficult to reach the request that 65% standard of building energy in china and the goal of China’s science and technology development in 2020 using traditional outer insulation technology. The several combinations of ordinary concrete (1) and bearing ceramsite concrete (2), styrofoam board of external thermal insulation for external wall (3) and cement-based glazed hollow bead insulation system (4) are made thermal calculations and cost analysis separately in this paper based on a practical project of Jiaozuo city. The results indicate that the combination of (2)+(4) is the best one, which reduces the energy saving rate, labor intensity, transportation weight, project cost by 74%, 20%, 30%-40% and 10% respectively.
Details
- ISSN :
- 16627482
- Database :
- OpenAIRE
- Journal :
- Applied Mechanics and Materials
- Accession number :
- edsair.doi...........f0e9cebfc82e8ccd337f18a1b6b01f0f
- Full Text :
- https://doi.org/10.4028/www.scientific.net/amm.71-78.353