Back to Search
Start Over
Face-to-Face Versus Video Assessment of Facial Paralysis: Implications for Telemedicine (Preprint)
- Publication Year :
- 2018
- Publisher :
- JMIR Publications Inc., 2018.
-
Abstract
- BACKGROUND Patients with facial nerve paralysis (FNP) experience challenges in accessing health care that could potentially be overcome by telemedicine. However, the reliability of telemedicine has yet to be established in this field. OBJECTIVE This study aimed to investigate the consistency between face-to-face and video assessments of patients with FNP by experienced clinicians. METHODS A repeated-measures design was used. A total of 7 clinicians assessed the FNP of 28 patients in a face-to-face clinic using standardized grading systems (the House-Brackmann, Sydney, and Sunnybrook facial grading systems). After 3 months, the same grading systems were used to assess facial palsy in video recordings of the same patients. RESULTS The House-Brackmann system in video assessment had excellent reliability and agreement (intraclass correlation coefficient [ICC]=0.780; principal component analysis [PCA]=87.5%), similar to face-to-face assessment (ICC=0.686; PCA=79.2%). Reliability of the Sydney system was good to excellent, with excellent agreement face-to-face (ICC=0.633 to 0.834; PCA=81.0%-95.2%). However, video assessment of the cervical branch and synkinesis had fair reliability and good agreement (ICC=0.437 to 0.597; PCA=71.4%), whereas that of other branches had good to excellent reliability and excellent agreement (ICC=0.625 to 0.862; PCA=85.7%-100.0%). Reliability of the Sunnybrook system was poor to fair for resting symmetry (ICC=0.195 to 0.498; PCA=91.3%-100.0%) and synkinesis (ICC=−0.037 to 0.637; PCA=69.6%-87.0%) but was good to excellent for voluntary movement (ICC=0.601 to 0.906; PCA=56.5%-91.3%) in face-to-face and video assessments. Bland-Altman plots indicated normal limits of agreement within ±1 between face-to-face and video-assessed scores only for the temporal and buccal branches of the Sydney system and for resting symmetry in the Sunnybrook system. CONCLUSIONS Video assessment of FNP with the House-Brackmann and Sunnybrook systems was as reliable as face-to-face but with insufficient agreement, especially in the assessment of synkinesis. However, video assessment does not account for the impact of real-time interactions that occur during tele-assessment sessions.
Details
- Database :
- OpenAIRE
- Accession number :
- edsair.doi...........f03d426155825e4b45b1aab4d58fdfff