Back to Search Start Over

Software Analysis of the Reinforced Concrete Beam with Additional Installation of Lightning Protection Cable

Authors :
Muhammad Arkam Che Munaaim
Koay Jye Yueh
Mustaqqim Abdul Rahim
Zuhayr Ghazaly
Abdul Naser Abdul Ghani
Source :
Materials Science Forum. 904:185-188
Publication Year :
2017
Publisher :
Trans Tech Publications, Ltd., 2017.

Abstract

Lightning protection system protects building structure from direct lightning impact. Embedding lightning protection cable inside concrete structure is widely use in practice now days. The objective of this research is to investigate the effect of installation of additional conductor cable inside concrete beam to its beam displacement and beam stress using finite element analysis software ABAQUS. The beam without additional conductor cable, with cable conductor installed at top and bottom reinforcement is modelled using ABAQUS. The results obtained from the three model is compared. As the result, the beam with additional conductor cable at top reinforcement shows minimum deformation and minimum Mises stress.

Details

ISSN :
16629752
Volume :
904
Database :
OpenAIRE
Journal :
Materials Science Forum
Accession number :
edsair.doi...........ef82c19375381a308638e5dbbc328ad8
Full Text :
https://doi.org/10.4028/www.scientific.net/msf.904.185